Bosch Appliances CC880 Home Security System User Manual


 
CC880/LP880, SC8016 | Operators Guide | 27.0 Basic Pager Reporting EN | 18
Bosch Security Systems | 6/04 | 920036O.OG.162
Figure 8: Basic Pager Display
Zone Normal - 0
Alarm - 1
Zone Bypassed - 2
Zone Trouble - 3
Disarmed - 8
Armed - 9
Normal - 0
Panic/Duress - 1
Fire Alarm - 2
Medical Alarm - 3
AC Normal - 0
AC Failure - 1
System Normal - 0
System Fault - 1
678 01200000 9000
123456 87
1
2
3
1 – Subscriber ID Number
2 – Zone Status
3 – System Status
Figure 8 shows the transmission came from the control panel with an ID number of 678 and that zone 2 is in
alarm. The figure also displays that zone 3 was manually isolated and the system armed.