CC880/LP880, SC8016 | Operators Guide | 21.0 Codepad ID and Buzzer Tone EN | 14
Bosch Security Systems | 6/04 | 920036O.OG.162
21.0 Codepad ID and Buzzer
Tone
If you press and hold down button [8], the tone of
the codepad buzzer changes. There are 50 different
tones to choose from between 1500 Hz and 5000 Hz.
If multiple codepads are installed, each codepad can
have a different tone.
If the system is partitioned into multiple areas, the
codepad displays the area that it is assigned to before
the tone of the buzzer starts to change.
Table 13: Codepad ID and Buzzer Tone Change
Zone Indicator Area Assigned
None Not Assigned
1 Area 1
2 Area 2
3 Area 3
4 Area 4
7 Master Partitioned Keypad
22.0 Partitioning
Your control panel can be partitioned or split into
four individual areas. Each areas can be operated
from one master partitioned codepad, or from
separate area addressable codepads.
22.1 Master Partitioned Codepad
Indicators
The indicators on a master partitioned codepad are
configured into four groups (such as, Zone
Indicators, Area On/Off Display, Area Display, and
Status Indicators). Refer to Figure 7. The following is
a description of what the indicators mean.
Figure 7: Master Partitioned Codepad
22.1.1 Zone Indicators
Zone indicators 1 to 8 show the status of each zone.
These zones belong to the area that displays the
AREA DISPLAY indicator. (For example, if an
indicator is displayed, that zone is unsealed. If the
indicator is not displayed, that zone is sealed.)
22.1.2 Area On/Off Indicators
The group of four AREA ON/OFF indicators display
the status of each area. (For example, if an indicator
is displayed, that area is armed. If the indicator is not
displayed, that area is disarmed.)
22.1.3 Area Display Indicators
The group of four AREA DISPLAY indicators show
which area the zones displayed belong to. All
functions entered at the keypad only affect the area
the keypad displays in the AREA DISPLAY. Press
the [#] key to toggle between each area.
22.1.4 Status Indicators
A group of four indicators display the following:
AUX Indicator
Displays when the control panel is using the
telephone line communicating with the receiving
party.
MAINS Indicator
Displays the status of the AC mains power. (For
example, if the indicator is illuminated, the AC
mains power supply is normal. If the indicator is
flashing, the AC mains power supply is disconnected
or failed.)
FAULT Indicator
Displays the status of the fault register. (For example,
if the FAULT indicator is flashing, the system
detected a fault that was not acknowledged. If the
FAULT indicator is illuminated, the fault is
acknowledged. If the FAULT indicator is not
illuminated, the system has no faults.)
PARTIAL Indicator
Only displays for an area armed in STAY Mode 1.
(For example, if the PARTIAL indicator displays, an
area is armed in STAY Mode 1. If the PARTIAL
indicator does not display, no areas are armed in
STAY Mode 1.)
22.2 Operation of Codepads in
Partitioning
Area Addressable Codepad Operations
If you have a system that is partitioned with area
addressable eight zone codepads, the operating
procedure is exactly the same as described for a non-
partitioned system except that all operations only
relate to the area the codepad is assigned to.
Master Partitioned Codepad Operations
If you have a system that is partitioned with a master
partitioned codepad installed, the operating
procedure is exactly the same as described for a non-
partitioned system, except that all operations only
relate to the area displayed by the AREA DISPLAY
indicator.