The appliance may be installed in any room subject to the
requirements of the current IEE regulations and, in Scotland, the
relevant electrical provisions of the Building Regulations with
respect to the installation of appliances in rooms containing
baths or showers.
If the appliance is installed in a room containing a bath or
shower, any switch or appliance control using mains electricity
must NOT be able to be touched by a person using the bath or
shower.
The appliance shall not be installed in a room or internal space
below ground level when it is intended for use with LPG propane
(G31). This does not preclude the installation into a room or
space which are basements with respect to one side of the
building but are open to the ground on the opposite side.
The appliance is NOT suitable for external installation.
The wall must be able to support the weight of the appliance.
Refer to Table 4.
The specified clearances must be available for installation and
servicing. Refer to Table 7 and Fig.2.
The appliance can be installed in a cupboard/compartment to
be used for airing clothes providing that the requirements of
BS6798 and BS5440/2 are followed.
The clearance between the front of the appliance and the
cupboard/compartment door should be not less than 25mm for
air circulation.
4. Siting The Appliance
6
Fig. 2. Appliance casing dimensions and
required clearances.
Side view
260mm
600mm*
30mm*
200mm*
5mm*
* Space required for installation and servicing. Refer to Table 7
Front view
390mm
5mm*
36mm
150mm
600mm
Fig. 3. Appliance pipework connections
Fixing clip
GAS
25mm
36mm
88mm
165mm
FLOW
RETURN
100mm
30mm
(Rear only flue)
Rear only flue
Rear only flue
External
flue turret
142mm