Bosch Appliances 7000 Home Security System User Manual


 
48 en | Configuration DINION capture 5000/7000
| 1.0 | 2012.01 Installation Manual Bosch Security Systems, Inc.
4.6.4 Connections submenu
Alarm output VMD,
External
device,
Night mode
active,
Filter toggle
VMD: - output relay closes on VMD
alarms.
External device: - make the output
relay available to remote
communication devices.
Night mode active: - output relay closes
when camera is in monochrome mode.
Filter toggle: - output relay closes just
before the IR filter starts moving and
opens when video level has stabilized
(2 to 3 seconds)
EXIT Returns to Install menu.
Item Selection Description
Item Selection Description
Sync. input High Z,
75 ohm
Select 75 ohm if the external sync
input is not terminated elsewhere.
Notch filter On, Off Switches notch filter on or off. The
notch filter can remove a Moiré pattern
or color artifacts caused by closely
spaced vertical lines or objects (e.g.
vertical security bars over windows).
Cable
compensation
Off, Default,
RG59, RG6,
Coax12
Cable compensation is used to avoid
the need for amplifiers in long distance
coaxial connections up to 1000 m
(3000 ft). For optimum results select
the coaxial cable type used or, if
unknown, select default.