DINION capture 5000/7000 Installing the DINION capture | en 23
Bosch Security Systems, Inc. Installation Manual | 1.0 | 2012.01
3.4 Preparing the Wiring
The DINION capture 5000 comes pre-wired with a single two-
wire power input lead and a single 75 ohm coaxial video cable
output lead terminated with a BNC connector. The DINION
capture 7000 comes pre-wired with a single two-wire power
input lead and two 75-ohm coaxial video cables, one cable for
each camera. On all units the video and power wires are
encased in an approximately 2 m long cable, the last 10 cm of
the cable the power and video breaks out separately.
3.4.1 Power Input Connections
A voltage regulator circuit allows for DC or AC operation
between 11-30 VDC and 24 VAC. It also provides protection
from voltage surges, transient spikes, and reversed voltage.
Connect power from a 24 VAC or 11–30 VDC Class 2 power
supply to the ferrule tipped power leads (red, black) from the
camera. Use minimum AWG18 stranded wire.
Note:
For a Class 2 AC/DC supply the polarity does not matter.
3.4.2 Video Connections
The DINION capture provides male BNC connector outputs at
the end of the cable. On the DINION capture 7000 the white
video cable is for the license plate camera and the red cable is
for the overview camera. A UTP adapter (VDA-455UTP) is
available as an optional accessory to allow a UTP video cable to
be connected to the BNC connector.
CAUTION!
Before proceeding, disconnect the power from the power
supply cable. Ensure that the voltage of the unit matches the
voltage and type of the power supply being used.