Beckett CF375 Burner User Manual


 
6104 BCF3 R02 Page 3
Before you begin . . .
The following resources will give you addional information for your installation. We suggest that you consult
these resources whenever possible. Pay particular attention to the appliance manufacturer’s instructions.
Appliance manufacturer’s instructions -Always follow the appliance manufacturer’s instructions for burn-
er installation, equipment and set-up.
1–800–OIL–BURN - Beckett’s technical services hot-line.
www.beckettcorp.com - Beckett’s website.
Hazard de nitions
Intended to bring special attention to information,
but not related to personal injury or property
damage.
NOTICE
Indicates a potentially
hazardous situation,
which, if not avoided, may result in person-
al injury or property damage.
Indicates a potentially
hazardous situation,
which, if not avoided, could result in death,
severe personal injury, and/or substantial
property damage.
Indicates an imminently
hazardous situation,
which, if not avoided, will result in death,
serious injury, or property damage.
Within the boundaries of the hazard warning, there will
be information presented describing consequences if the
warning is not heeded and instructions on how to avoid
the hazard.
To the Owner:
Thank you for purchasing a Beckett burner for
use with your heating appliance. Please pay attention
to the Safety Warnings contained within this instruc-
tion manual. Keep this manual for your records and
provide it to your quali ed service agency for use in
professionally setting up and maintaining your oil
burner.
Your Beckett burner will provide years of ef cient
operation if it is professionally installed and main-
tained by a quali ed service technician. If at any time
the burner does not appear to be operating properly,
immediately contact your quali ed service agency
for consultation.
We recommend annual inspection/service of your
oil heating system by a quali ed service agency.
Agency approvals
UL listed to comply with ANSI/UL296 and certi ed to
CSA B140.0.
Accepted by N.Y.C. M.E.A.
Other approvals may be available and must be speci ed at
time of order.
Speci cations
Fuels
U.S. #1 or #2 Fuel Oil only
(ASTM D396)
Canada #1 Stove Oil or #2
Furnace Oil only
Firing range 1.65 to 3.75 GPH
Motor 1/7 HP 3450 RPM
120/60 hz standard
1.7 amps @ 120 VAC
Optional voltages:
(60 hz or 50 hz) –
Ignition Trans. 120V/12,000V
Housing Cast aluminum
Fuel unit 100 - 200 PSIG
Oil nozzle 45° - 70° solid
Shipping wt. 25 lbs.