Beckett CF375 Burner User Manual


 
Page 14 6104 BCF3 R02
Check motor current. The amp draw should not exceed the
nameplate.
Check all wiring for secure connections or insulation
breaks.
Check the pump pressure and cutoff function.
Check primary control safety lockout timing.
Check ignition system for proper operation.
Inspect the vent system and chimney for soot accumula-
tion or other restriction.
Clean the appliance thoroughly according to the manufac-
turer’s recommendations.
Check the burner performance. Refer to the section “Set
combustion with test instruments”.
It is good practice to make a record of the service per-
formed and the combustion test results.
Monthly maintenance
— by owner
Observe combustion air openings and vent system
for integrity. Openings must be clean and free of
obstructions.
Check oil lines and ttings to verify there are no leaks.
Observe burner ignition and performance to verify smooth
operation.
Shut the system down if you observe abnormal or
questionable operation. Call a quali ed service agency for