WIRING
FACTORY WIRING
All units are fully factory wired. Multispeed blowers
are factory wired on high speed for cooling/manual fan
operation. Heating speeds are wired for the largest
input and may need lower speed for field installed low
input nozzle. If replacement wire is necessary, use 105
degrees C minimum. See electrical data, Table 3.
FIELD WIRING
All wiring must conform to the National Electrical
Code and all local codes. A separate fuse or breaker
should be used for the furnace.