Bard FLR110D60F Furnace User Manual


 
Manual 2100-422M
Page 12 of 42
OIL LINE PIPING
First determine whether the pipe system is to be a
single line system or a two line system. All
connections must be absolutely air tight or you will
have a malfunction of the burner. When installing the
piping, a good oil filter should be installed close to the
burner. A single line system is recommended for
gravity feed.
A typical single inside tank installations shown in
Figure 6. For installation details for this and other tank
configurations, refer to NFPA31 -- latest edition. All
tank and pipe setups must comply with NFPA31.
BECKETT AFG OR NX OIL BURNER
This furnace is equipped with a high static Beckett AFG
or Beckett NX oil burner which is designed to produce
adequate draft in nearly any vertically vented
application. The burner employs the latest time tested
controls of the highest quality. The controls consist of a
high voltage Beckett solid state igniter, a Beckett
“CleanCut” oil pump with an integral solenoid valve,
and a Genisys 7505 primary control.
FIGURE 6
TYPICAL SINGLE INSIDE TANK INSTALLATION
6"
2" Cap
Vent Cap
2" Fill Pipe
1-1/4"
Vent Pipe
Return Line
Guage
Bushing,
2" x 1-1/2" or
1-1/4"
Oil Filter
3/8" O.D. Copper
Fuel Tubing
3/8" x 3/8"
Adapter
Gate Valve
3/8" x 4"
nipple
Bushing
Legs (either 1-1/4"x10"
or 1-1/2"x10" nipples)
Oil
Tank
MIS-1823