Avalon Stoves Avanti PS Stove User Manual


 
32 Safety Label
Travis Industries Newport 290902
WARNING - DO NOT REMOVE OR COVER THIS LABEL
R
Listed Pelletized
Solid Fuel Burning Appliance
Also for Use in Mobile Homes
Model: Avanti-PS
Serial No:
Report No. 476-1407-00 (May, 1997) Tested to: UL 1482/ULC S627/CSA B366.2/ASTM E 1509-95
Maximum Input Rating: 3.5 lbs (1.60kg)/hr Electrical Rating: 115V, 60Hz, 3 Amp
This pellet fired appliance has been tested and listed for use in manufactured homes in accordance with
Oregon Administrative Rules 814-23-900 through 814-23-909.
Install and use only in accordance with the manufacturers installation and operating instructions. Contact
local building or fire officials about restrictions and installation inspection in your area. Use only listed
3 in./75 mm or 4 in./100 mm diameter listed type L Vent complete with components. See manufacturers
installation instructions for precautions required for passing a vent through a combustible wall or ceiling.
Do not connect this appliance to a vent serving another appliance.
Minimum Clearance to Combustible Materials (Measured to Stove Top)
BACKWALL
LEFT SIDEWALL
FLOOR PROTECTOR
A
C
HH
B
G
E
ADJACENT WALL
ADJACENT WALL
D
D
RIGHT SIDEWALL
Interior Vertical Horizontal Through
Flue Installation the Wall Installation
Left Sidewall A 9” 9”
Right Sidewall B 9” 9”
Backwall C ** 3”
Corner D 2” 2”
Flue Vent E 3” 3”
Maximum alcove depth 48 in/1220 mm, min ceiling height 60 in/1525 mm.
Combustible floor must be protected by a non-combustible material, extending to the front (G) 6 in/150 mm
and to the sides (H) 0 in/0 mm.
** This dimension will vary depending on brand of listed type L vent. See manual for details.
For use with 1/4 in/6 mm to 5/16 in/7 mm diameter pelletized wood fuels only.
Replace glass only with 5 mm ceramic glass.
Do not route power cord beneath heater. The space beneath the heater must not be obstructed. Outside
combustion air is mandatory for mobile home installation. Do not obstruct combustion air openings. Operate
only with viewing door and ash removal tray tightly closed. Keep all furnishings well away from heater.
Mfg. by TRAVIS INDUSTRIES, INC.
10850 117th Pl N.E.
Kirkland, WA 98033
TM
HOT WHILE IN OPERATION. DO NOT TOUCH. CONTACT MAY CAUSE
CAUTION: SKIN BURNS. KEEP FURNISHINGS AND COMBUSTIBLE MATERIAL
A CONSIDERABLE DISTANCE AWAY. SEE NAMEPLATE AND INSTRUCTIONS. DO NOT
OVERFIRE. IF HEATER OR CHIMNEY CONNECTOR GLOWS, YOU ARE OVERFIRING. INSPECT
AND CLEAN CHIMNEY AND CONNECTOR FREQUENTLY. UNDER CERTAIN CONDITIONS OF
USE, CREOSOTE BUILDUP MAY OCCUR RAPIDLY. DO NOT OVERFIRE. IF UNIT SHUTS DOWN
OFTEN YOU ARE OVERFIRING. TYPE OF FUEL: PELLETIZED WOOD FUEL ONLY.