8 Installation
Travis Industries Newport 290902
Venting the Pellet Stove
• PELLET VENT MUST MAINTAIN A MINIMUM 3" CLEARANCE TO ANY
COMBUSTIBLE (INSTALL VENT AT CLEARANCES SPECIFIED BY THE
VENT MANUFACTURER).
• DO NOT CONNECT THE PELLET VENT TO A VENT SERVING ANY
OTHER APPLIANCE OR STOVE.
• DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM
OF THIS UNIT.
• USE AN APPROVED WALL THIMBLE WHEN PASSING THE VENT
THROUGH WALLS AND A CEILING SUPPORT/FIRE STOP SPACER
WHEN PASSING THE VENT THROUGH CEILINGS (MAKE SURE TO
MAINTAIN 3" CLEARANCE TO ANY COMBUSTIBLES.
• No more than 180° of elbows (two 90° elbows, or two 45° & one 90° elbow, etc.).
Maximum Venting
Distance:
• Vent must have a
support bracket every
5' of pellet vent when
exterior of structure
• If the heater is
installed at an altitude
over 4,000' use 4"
diameter for all
applications
0 Feet
5 Feet
10 Feet
(max.)
0 Feet
5 Feet
10 Feet
15 Feet
20 Feet
25 Feet
30 Feet
33 Feet
(max.)
Use 4” diameter
vent if venting
into this shaded
region.
Use 3” or 4”
diameter
vent if
venting into
this shaded
region.
The vent height and run
must not exceed the
distance shown in the
shaded region shown to the
right.
NOTE: To achieve optimum
performance, we
recommend keeping the
vent as short as possible
(horizontal run especially).