10 Installation
Travis Industries Newport 290902
Mobile Home Requirements
• Outside air is required (used for
combustion) - see the directions
below.
• The heater must be bolted to the
floor (Some states do not require
this; check with your local building
department). See the illustration
to the right.
• The heater must be grounded to
the steel chassis of the mobile
home (Some states do not require
this; check with your local building
department).
WARNING: DO NOT INSTALL IN
SLEEPING ROOM.
CAUTION: THE STRUCTURAL
INTEGRITY OF THE
MANUFACTURED HOME
FLOOR, WALL, AND
CEILING/ROOF MUST BE
MAINTAINED.
7/16”
Socket
Remove the four
bolts holding the
stove to the pedestal.
Lift the stove off of the
pedestal and place it on a
piece of wood so that the
ash pan trap door does
not become damaged.
Remove the ash pan
(see page 27).
Use the included lag bolts to screw
the pedestal to the floor. Then
replace the stove and ash pan.
1/2”
Socket
a
b
c
d
Outside Air (used for combustion)
• Must not be drawn from an enclosed space (garage, unventilated crawl space).
HINT: Travis Industries strongly suggests outside air for all residential installations, especially for
those that are energy efficient, air tight homes.
WARNING: During a power outage there is a
possibility of some smoke entering
the room if an outside air
connection is not used.
• Must not be over 15' long.
• Must be made with 1 3/4" diameter
or larger metal or aluminum duct
with a metal screen attached to the
end to keep out rodents (P.V.C. or
other combustible materials may
not be used). Use the Travis
Industries Outside Air Kit (part #
99200136).
• Must not terminate above or within
1' of the chimney termination.
• Must have a rain cap or down-
turned elbow to prevent water
from entering.
• Must be located so that it will not
become plugged by snow or other
material.
7-5/8"
10-3/4"
1-3/4" Diameter
Flex Duct
Select a location between
framing members for the
outside air hole.
Rain
Hood with
Rodent
Screen
Silicone
Cut a minimum 2"
diameter hole in
the wall.
Seal the vent with
silicone.
Wall
Cover
Plate
We recommend
the use of the
Travis Industries
Outside Air Kit
(Part # 99200136)
Silicone
Seal the area around
the tube to prevent air
from entering the
wall.
Silicone
Silicone