Avalon Stoves Avanti PS Stove User Manual


 
Operation 17
Travis Industries Newport 290902
Loading Pellets
Lift the hopper lid to its vertical position. Pour pellets into the hopper until full. NOTE: The hopper
holds approximately 55 pounds of pellets.
P
e
t
e
l
s
l
Make sure pellets
are not left on this
heat shield.
The front edge of the hopper lid
becomes very hot, do not touch the
area below the handle.
WARNING:
The Two Modes of Operation:
Manual
Manual mode requires the user to turn
the heater on and off manually.
Auto (requires a thermostat)
Auto mode allows you to use a
thermostat to control room
temperature. The stove automatically
turns on when the temperature drops
below the thermostat setting. Once the
stove reaches operating temperature,
the stove then runs at the heat output
setting selected.
Switching Modes While in
Operation
Whenever the stove is switched from
one mode to another while in
operation, the stove will enter the "start-
up" sequence for a minimum of 20
minutes.
HIGH
DISCONNECT POWER BEFORE SERVICE
REMOTE
AUTO
MANUAL
H
E
A
T
O
U
T
P
U
T
MED
LOW
AUGER
FAULT
AUTO
OFF
MANUAL
H
E
A
T
F
A
N
UP
DOWN
UP
DOWN
MANUAL
MANUAL
START
AUGER
TRAVIS INDUSTRIES
HOUSE OF FIRE
TM
Use the mode
switch to
determine the
mode.
These indicator lights
are used to determine
which mode you are in.
NOTE: if using a
modulating remote, this
light will come on to
indicate the remote is
controlling the heater.