Avalon Stoves Freestanding Stove Stove User Manual


 
12 Installation (for qualified installers only)
Travis Industries 93508115 4050113
Approved Vent Configurations
Restrictor
Position
A restrictor is built
into the appliance to
control the flow rate
of exhaust gases.
This ensures proper
flames for the wide
variety of vent
configurations.
Depending upon
the vent
configuration, you
may be required to
adjust the restrictor
position. The charts
for approved vent
configurations
describe which
position the vent
restrictor must be in.
Remove the nuts holding
the stove top in place
(see the illustration
below). Lift the stove top
off the stove.
To Adjust the RestrictorTo Access the Restrictor
NOTE:
The restrictor is
shipped in
position #1.
This restrictor is
in position # 6
Lift the cotter pin out.
a
Slide the restrictor
adjustment rod in.
b
Replace the cotter pin
through the correct
hole on the restrictor
adjustment rod.
c
Restrictor
Positions
# 2
# 4
# 6
# 3
# 5
# 1
3/8" Nutdriver
Measuring
Vent Lengths
Vent Horizontal Run
(measure from the closest edge of
the starter section to the end of the
termination)
Vent Height is calculated
to the top of the vent on
horizontal terminations
and to the top of the
termination on vertical
terminations.
Vent