Aurora of America 442 Water Pump User Manual


 
MAINTENANCE (continued) PAGE 15
7. PUMP ASSEMBLY
CAUTION: READ THIS ENTIRE PROCEDURE BEFORE CONTINUING.
Following are step-by-step instructions for assembly of the pump and are essentially the reverse order of the
instructions for disassembly.
A. Thoroughly clean all parts to remove oil, grease and foreign material. Inspect for wear or damage and
replace if required. Remove all parts to a clean and dust-free location for assembly. Gaskets, grease
seals and bearings should not be reused and should always be replaced with new parts.
B. If the impeller wear rings (17) require replacement, they are a light press fit and will be secured by one
of the following methods. You should proceed as follows:
Rings Secured With Loctite: Apply a light film of Loctite No. 290 to the impeller part of the
impeller/wear ring fit and install the rings.
CAUTION: BE CAREFUL NOT TO DRILL THROUGH THE IMPELLER AND BE SURE TO PRESS
THE WEAR RING COMPLETELY IN PLACE. THEY SHOULD BE FIRMLY BUTTED
AGAINST THE CORRESPONDING IMPELLER SHOULDER.
Rings Secured With Set Screws: Press the rings in place and drill and tap them using the same size
and number of setscrews as originally provided. The new holes should be 15
o
to 20
o
from the old
holes. Install and tighten the set screws.
CAUTION: IF THE SHAFT SLEEVES ON YOUR PUMP ARE SECURED WITH LOCTITE ONLY,
REFER TO THE SHAFT SLEEVE INSTALLATION INSTRUCTIONS BEFORE
INSTALLING THE IMPELLER.
C. Install the impeller key (102) in the shaft (4) and slide the impeller (1) over the key, centering it between
the shaft shoulders as shown in Figure 5.
FIGURE 5
CAUTION: THE LINEAR POSITION OF THE IMPELLER MUST BE OBTAINED AND THE SHAFT
SLEEVES MUST BE PROPERLY LOCATED. REFER TO FIGURE 5 ON THE
PREVIOUS PAGE OF THIS MANUAL. IF PROVIDED, THE SHAFT SLEEVE NUTS
MUST BE TIGHTENED WITHIN 10 MINUTES AFTER THE LOCTITE IS APPLIED. TO
ACCOMPLISH LINEAR POSITIONING OF THE IMPELLER, LEAVE AN EQUAL
AMOUNT OF SHAFT OR SHAFT THREADS EXPOSED ON EACH END OF THE
SHAFT AFTER ASSEMBLY IS COMPLETED. ALLOW 4 HOURS FOR THE LOCTITE
TO CURE BEFORE COMPLETING THE PUMP ASSEMBLY.