Suction pipe cleaning (after every use)
Thoroughly clean the suction pipe (6, Fig. F) inside, up to the suction inlet, with pressurized water.
Carefully check the suction pipe gasket (5, Fig. F) for integrity, and replace it if necessary.
Suction lter and fan cleaning (after every use)
Inside the hopper, remove the fasteners (16, Fig. F) of the suction lter (15).
Remove the suction lter (15, Fig. F).
Operating in the compartment (13, Fig. F), wash the fan (1, Fig. P) with pressurized water; check that all fan sectors (2) are
clean.
Clean the suction lter (1, Fig. Q) with pressurized water.
Install the suction lter and secure it with the fasteners (16, Fig. F).
Remove the lid support rod (17, Fig. F) and lower the hopper (7, Fig. G) according to the instructions shown in the relevant
paragraph.
Turn the ignition key (24, Fig. D) to OFF position and remove it.
Breather lter cleaning (after every use)
With a ladder and the help of an assistant, disengage the fasteners (26, Fig. G) of the breather lter hood (27).
Open the hood (1, Fig. R) and install the safety pins (2).
Remove the mounting screws (1, Fig. S), then remove the breather lter (2).
Clean the breather lter (1, Fig. T) with pressurized water.
Install the breather lter and its hood performing steps from 15 to 17 in reverse order.
Suction fan bearing lubrication (after every use)
Open the left side lid (9, Fig. G).
Lubricate the suction fan bearings with the grease nipples (1, Fig. U).
Grease quantity to be applied:
4 - 5 pumping, in case of a manual pump.
15 - 20 seconds of injection, in case of an air pump.
Close the left side lid (9, Fig. G).
DUST CONTROL SYSTEM NOZZLE AND FILTER CLEANING
WARNING!
Protect body parts (eyes, hair, hands, etc.) properly, when performing cleaning procedures using compressed
air or water gun.
Preliminary operations
Engage the parking brake (13, Fig. E).
Turn the ignition key (24, Fig. D) to OFF position and remove it.
Cleaning of nozzles and lters on side brooms
Unscrew the ring nuts (1, Fig. V).
Remove and clean the nozzles (2, Fig. V) and lters (3) with compressed air. Remove calcium deposits. If necessary, replace
the lters (3).
Install the lters and nozzles, and secure them with the ring nuts.
Cleaning of nozzles and lters in the suction pipe, from suction inlet to hopper
Empty the hopper (7, Fig. G); if it contains a small quantity of waste, it is not necessary to dump it.
Drive the machine on a solid and level ground, then engage the parking brake (13, Fig. E).
Lift the hopper (7, Fig. G), according to the procedure shown in the relevant paragraph.
Turn the ignition key (24, Fig. D) to OFF position and remove it.
To avoid that the hopper lowers by accident, install the lifted hopper support rods (3, Fig. F), according to the instructions
shown on the relevant paragraph.
Operating inside the suction pipe (6, Fig. F), with a 0.55 in (14 mm) socket wrench, unscrew the nozzle (1, Fig. X) and remove
the lter (2) (check the actual position of the nozzle).
Clean the nozzle (1, Fig. X) and lter (2) with compressed air. Remove calcium deposits. If necessary, replace the lter (2).
Install the lter and nozzle in the reverse order of removal.