ADTRAN 610200094 Air Conditioner User Manual


 
Adtron I35MB Operations Manual
Rev. 003, PN: 610200094
8
Mirror Control Button Functions
The following figure shows the location of the mirror control buttons and LEDs on
the I35MB.
Bank 0 Mirror control
Bank 1 Mirror control
Buzzer Reset
Figure 8 Mirror Control Button operations
The following table describes the different operations using the Mirror Control
button on either bank. Press and hold Mirror Control button to activate the functions
listed in Table 2.
Button Press Duration Bank Access LED Feedback Function
0 – 5 seconds LED flashes slow (1/sec) Power up or down bank
5 – 10 seconds LED flashes medium (2/sec) Mirror Rebuild
10 – 15 seconds LED flashes fast (4/sec) No Operation
15 – 20 seconds LED solid on Reserved
> 20 seconds LED off No Operation
Table 2 Mirror Control Button operations
Functions marked reserved are for Adtron factory use only. Contact
technical support for more details. In the case of a button press duration
that reaches 15 seconds, DO NOT release until after 20 seconds to save
future operations.
Advanced Operations
The individual banks may be taken off-line (powered down and/or replaced) at any
time, for preventative maintenance or due to a failure. However, taking a bank
offline automatically faults the mirror, requiring a rebuild. To clear a hard or soft
fault, the rebuild must complete.
Managing Faults
The I35MB has two fault indicators: hard and soft. Refer to page 19, for the specific
bank fault LED indicators to interpret these two types of faults.