ADT Security Services 9600 Smoke Alarm User Manual


 
2SWLRQDO0RGXOHVDQG'HYLFHV ,QVWDOODWLRQ
8QLPRGH31& 
2.6.5 Digital Communicator and Annunciators
2.6.5.1 ADT-UDACT Digital Alarm Communicator/Transmitter
7KH$'78'$&7WUDQVPLWVV\VWHPVWDWXVWR8/OLVWHG&HQWUDO6WDWLRQUHFHLYHUVYLD
WKHSXEOLFVZLWFKHGWHOHSKRQHQHWZRUN,WLVFDSDEOHRIUHSRUWLQJXSWRVRIWZDUH
]RQHVRUXSWRDGGUHVVDEOHSRLQWV7KH$'78'$&7FDQEHPRXQWHGUHPRWHO\LQ
D8%6)RU$'7$%65)HQFORVXUHRULQWKHSDQHOFDELQHWXVLQJWKH31%5.7
8QLYHUVDO%UDFNHWUHIHUWR$'78'$&70DQXDO7KH8QLPRGHLV
FRPSDWLEOHZLWK$'78'$&7VRIWZDUH8'$&7DQGDERYH
3URJUDPPLQJ
7KH8QLPRGHPXVWEHSURJUDPPHGWRRSHUDWHZLWKWKH$'78'$&75HIHUWR
$QQXQFLDWRUV8'$&7RQSDJHIRUFRQWUROSDQHOSURJUDPPLQJLQIRUPDWLRQ
2.6.5.2 ADT-ACM-8R Relay Control Module
7KH$'7$&05PRGXOHSURYLGHVHLJKW)RUP&UHOD\VZLWKFRQWDFWVUDWHGIRU
DPSV:KHQLQVWDOOHGZLWKDQ8QLPRGH)$&3WKH$'7$&05PRGXOHV
SURYLGHUHOD\DFWLYDWLRQIRUHDFKRIWKHSRVVLEOH)$&3]RQHVSOXVVSHFLDOIXQFWLRQV
2SWLRQVH[LVWWRDOORZIRUDODUPRQO\RUDODUPDQGWURXEOHDFWLYDWLRQSHU]RQH2XWSXW
DFWLYDWLRQIRUJHQHUDODODUPJHQHUDOWURXEOHJHQHUDOVXSHUYLVRU\1$&IDXOW$&IDLO
ZDONWHVWVWDUWDQGEDWWHU\WURXEOHDUHDOVRDYDLODEOH7KH$'7$&05FDQEH
PRXQWHGUHPRWHO\LQDQ$'7$%65)DQQXQFLDWRUVXUIDFHPRXQWEDFNER[RULQWKH
SDQHOFDELQHWXVLQJWKH31%5.78QLYHUVDO%UDFNHW5HIHUWRWKH$'7$&0
5PDQXDOIRULQIRUPDWLRQRQVHWWLQJPRGXOHVZLWFKHVIRUDGGUHVVLQJDQGUHOD\
IXQFWLRQV
2.6.5.3 BRKT-9600 Universal Bracket Installation
7KHRSWLRQDO%5.78QLYHUVDO%UDFNHWFDQEHXVHGWRPRXQWVSHFLILFPRGXOHV
LQVLGHWKH8QLPRGHFDELQHW7KH%5.7PRXQWVWRWZRVWXGVORFDWHGLQWKH
ORZHUULJKWFRUQHURIWKHFRQWUROSDQHOFDELQHWDVLOOXVWUDWHGEHORZ,WLVVHFXUHGWRWKH
3(0VWXGVRQWKHEDFNZDOORIWKHFDELQHWZLWKWZRVXSSOLHGKH[QXWV
,03257$17:KHQWKH%5.7LVLQVWDOOHGWKH8QLPRGHFDELQHWFDQ
KROGDPD[LPXPRIWZR$PS+RXUEDWWHULHVZLWKWKHRULHQWDWLRQLOOXVWUDWHGEHORZ
Reference
Manual
See Page
Reference
Manual
+BATTERY-
LCD DISPLAY
KEYPAD I/F
1
2
3
OPT DACT
HOT
CB1
J3
J12
J2
TB1
TB2
TB3
JP3
JP2
JP8
JP4
JP7
JP5
JP6
J17
J16
J6
J8
J7
JP10
JP11
CUT TO
DISA BLE
LOCAL
CHARG ER
DISA BLE
GND
FLT
CUT TO
MONITOR 4XTM
OPT SLC
4XTM OPT BD
TB4
TB5
TB6 TB7 TB8
NEUTEARTH
1
4
*
2
5
0
3
6
#
1
st
EVENT
ABC
DEF
GHI
JKL MNO
PRS
TUV WXY
QZ
-/.
CLR
789
ESC
ENTER
RECALL
ACK/STEP
ALARM
SILENC E
DRILL
HOLD 2 SEC
RESET
MODE
MAI N TEN ANC E
GROUND
BATTERY
DISABLED
ALA RM
SILENCED
TROUBLE
SUPERVISORY
FIRE ALARM
AC POWER
Figure 2.13 BRKT-9600 Bracket Installation
Mount BRKT-9600 to PEM
studs on back of cabinet
using supplied hex nuts.
Unimode 9600 Cabinet
96brkmnt.cdr