Appendix A: Specifications
20
Appendix A: Specifications
Measurements
Globe temperature, dry bulb temperature, wet bulb temperature, % relative humidity,
WBGTin, WBGTout, WBGT weighted average (if 3 sensor sets), and Heat Index /
Humidex.
Temperatures given in Celsius or Fahrenheit.
Data Logging
Records and prints all measurements at user selected interval of 1, 2, 5, 10, 15, 30,
or 60 minutes. 128K bytes of data memory.
Languages
• English, French, Spanish, Italian, German
Housing
Designed water resistant to a light rain or mist. If rain is frequent, best practice
would be to remote the sensor bar and keep the instrument sheltered.
Size
• Height 9.2in (23.5cm); Width 7.2in (18.3mm); Depth 3.0in (7.5mm)
• Dimensions include mounted sensor assembly
Weight
• 2.6 lbs. (1.2 kg) with mounted sensor assembly
Sensor Types
• Temperature: 1000 ohm platinum RTD
• Humidity: Integrated circuit with capacitive polymer sensor
Accuracy
• Temperature: +/-0.5°C between 0°C and 120°C
• Relative humidity: +/- 5% between 20 to 95% (non-condensing)
Operating Temperature Range
• Sensor Assembly: -5°C to +100°C
• Electronics: -5°C to 60°C
Appendix A