4. Press
VIEW
TEMP
once. The letter O will change
to the letter U, representing the unoccu-
pied heating temperature (HEAT U).
5. Press either or to change the
temperature to your selected HEAT U set-
ting.
6. Press
RUN
PRGM
.
7. Press
SYSTEM
SWITCH
until COOL is displayed.
8. Press
VIEW
TEMP
once. The display will show
COOL and O, representing the occupied
cooling temperature (COOL O).
9. Press either or to change the
temperature to your selected COOL O
setting.
10. Press
VIEW
TEMP
once. Press or to
set your selected COOL U (unoccupied
cooling) setting.
11. Press
RUN
PRGM
.
Enter Heating Program
1. Press
SYSTEM
SWITCH
until HEAT is displayed.
2. Press
VIEW
PRGM
once. MO, the abbreviation for
Monday, and the letter O, representing the
occupied heating period, will appear in the
display. Also displayed are the currently
programmed start time for the occupied
heating period and the currently pro-
grammed HEAT O temperature.
EXAMPLE: