Whirlpool CA8WR42 Air Conditioner User Manual


 
C
Q
P
-0
El
Electrical Shock Hazard
Plug into a grounded 3 prong
outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these
instructions can result in
death, fire, or electrical shock.
If codes permit and a separate ground
wire is used, it is recommended that a
qualified electrician determine that the
ground path is adequate.
Check with a qualified electrician if you are
not sure air conditioner is grounded.
A three-wire, single-phase, 60-Hz, AC-only,
electrical supply is required on a separate
circuit. A 15-<amp time-delay fuse or circuit
breaker is required. Copper wire (#14
gauge) is required. The fuse size must not
exceed the circuit rating specified on the
model <and serial label.
The model and serial label
(A)
is located
behind the front panel above the coil area.
This label lists the BTU capacity, amperage,
voltage and refrigerant charge requirements.
Recommended grounding
method
For your personal safety, this air conditioner
must be grounded. This air conditioner is
equipped with a power supply cord
(B)
with a
.l-prong ground plug (C). To minimize
possible electrical shock hazard, the cord must
be plugged into a mating, 3-prong grounding-
type wall receptacle
(D),
grounded in
accordance with all local codes and
ordinances. If a mating 3-prong grounding-
type wall receptacle is not available, it is the
consumer’s responsibility to have a properly
grounded, s-prong wall receptacle installed by
a licensed installer.
It is the customer’s responsibility:
l
To contact a qualified electrical installer.
l
To assure that the electrical installation is
adequate *and in conformance with National
Electrical Code, kNSL/NFPA 70 - latest
edition,* sand all local codes and ordinances.
Copies of the standards listed may be obtained
from:
* National Fire Protection Association
Batterymarch Park
Quincy, Massachusetts 02269
Specific electrical requirement7 are listed
below. Follow the requirements for the rating
on the model and serial rating label.
l
115 volt - 103.5vmin.. 126.5~ max.
l
7.5.amp rating or less-a double outlet is
acceptable.
l
7.6 - through 12.amp ratings - use only a
single outlet and a separate circuit.
Peligro de Choque El6ctrico
Conecte a un contacto de pared
de conexi6n a tierra de 3
terminales.
No quite el terminal de conexi6n
a tierra.
No use un adaptador.
No use un cable el6ctrico de
extensi6n.
No seguir estas instrucciones
puede ocasionar la muerte,
incendio o choque el6ctrico.
Consulte con un electricista calificado
para asegurarse de que el acondicionador
de aire esti debidamente puesto a tierta.
Se requiere un suministro elCctric0 monof&ico
de tres alambres, de 60 Hz, ~610 de CA, en un
circuit0 separado.
Se requiere un fusible de retard0 de 15 amperes
o un disyuntor. Use solamente alambre de cobre
(calibre #14). El vdrnaio de1 fusible no debe
exceder la cltiificacibn de1 circuit0 especificada
en la etiqueta de modelo y serie.
La etiqueta de modelo y serie
(A)
se encuentra
detr& del panel debntero, sobre el $ea del
serpentin. Ma etiqueta indicd kd capacidad
BTU, el amperaje, el voltaje y 10s requerimientos
de carga refriger~ite.
Para su seguridad personal, este
Mktodo recomendado para
acondicionador de aire debe ser puesto a tierra.
Este acondicionador de aire estl equipado con
la puesta a tierra
un cord6n el&trico
(B)
provisto de un enchufe
con clavija tripolar (C) de conexidn a tierra.
Para reducir a un minim0 el riesgo posible de
un choque el&trico, el cord& debe enchufarse
en un tomacorriente mural para clavija con
3 terminales
(D),
puesto a tierra de acuerdo
con todos 10s cddigos y reglamentos locales. Si
no se dispone de un tomacorriente para clavija
tripolar, es responsabilldad de1 cliente hater
instalar un tomacorriente para clavija con tres
terminales debidamente puesto a tierra por un
electricista con licencia.
Es responsabilidad del cliente:
l
Llamar a un instalador elkctrico calificado
l
Asegurarse de que la instalacibn elCctrica es
adecuada y de acuerdo con el CBdigo National
de Energia, AXWNFPA 70, liltima edicGn*, y
todos 10s cddigos y reglamentos locales.
Pueden obtenerse copis de Izs norm= seimlad;LF
del:
* National Fire Protection Association
Batterymarch Park
Quincy, Massachusetts 02269
Los requerimientos el&tricos especificos se
indican abajo. Siga 10s requerimientos de la
ckGficaci6n en ki etiqueta de modelo )
clasificaci6n de serie.
l
115 voltios (103,5 min. - 126~5 mti,)
l
clasificaci6n de 7,5 amperes o menos - es
aceptable un tomacorriente doble.
l
clasificaciones de 7,6 a 12 amperes - use
ilnicamente un solo tomacorriente y tin
circuito separado.
Risque de choc 6lectrique
Brancher I’appareil uniquement
sur une prise ti 3 alv6oles reli& 5
la terre.
Ne pas enlever la broche de
liaison & la terre.
Ne pas utiliser un adaptateur.
Ne pas utiliser un cdble de
rallonge.
Le non-respect de ces
instructions peut causer un
d&z&s, un incendie ou un
choc 6lectriaue.
Si un conducteur distinct de liaison g la
terre est utilisk lorsque les codes le
permettent, on recommande qu’un
Clectricien qualit% vkrifie la qualit de la
liaison g la terre.
En
GlS
de doute quant :d la qualit de la liaison iI
la terre de cet appareil, contacter un electricien
qualifie.
L’appareil doit &tre aliment6 par un circuit
indbpendant a trois fds (monophase, 60 Hz, CA
seulement). Le circuit doit 3re protQ+ par un
disjoncteur ou un fusible temporise de 15
amperes. IJn fil de cuivre (cahbre 14 est requis).
L’ampbrage du fusible ne doit pas exckder le
maximum prescrit sur la plaque signalf3ique.
011
trouve le numero de modkle et le num&o de
skrie sur k~ plaque signalbtique
(A)
derrihre le
panneau aydnt au-dessus des serpentins. La
plaque signalktique indique la capaciti thermique
(BTU), les caract&istiques Clectriques et la
charge de rifrigkrant B utiliser.
Pour la securite personnelle des utihsateurs, il
hut
que ce climatiseur soit relii :d la terre. Ce
Mkthode recommandee
climatiseur est aliment6 par un cordon
klectrique
(B)
comportant une fiche de
de liaison g la terre
branchement (C) B trois broches, pour liaison
i la terre. Pour minimiser le risque de choc
Clectrique, brancher le cordon d’alimentation
sur une prise de courant murale
(D)
compatible a trois alvioles, reliee B ki terre
conformCment aux prescriptions de tous les
codes et r@,lements locaux en vigueur. Si une
prise de courant compatible avec la fiche de
branchement n’est pa disponible, c’est au
client qu’incombe l’obligation de faire installer
une prise de courant murale a 3 alvkoles
convenablement reliee P la terre, par
uu
electricien qualifik.
C’est au client qu’incombe kd responsabilitk de:
l
Contacter un c!lectricien qualifii
l
Veiller :d ce que I’installation electrique soit
r&dGe adkquatement et en conformite avec
les prescriptions du Code national des
installations Clectriques, WSIA’FPA 70
(dernikre Cdition*), et de tous les codes et
r+$emena
locdux
en vigueur.
On peut obtenir on exemplaire des normes
mention&es B I’adresse suivante:
*National Fire Protection Association
Batterymarch Park
Quincy, Massachusetts 02269
Le lableau ci-dessous indique les
caracteristiques electriques sp&ifiqiies j
respecter. Respecter les exigences indiquCes
sur la plaque signal&ique.
. 115 volts - 103,5v min., 126,;~ may.
l
7,5 amp
ou
moins une double prise est
acceptable.
l
7,6 :d 12 ampkres inclusivement - n’utiliser
3