Waterford Appliances T25-NG Stove User Manual


 
Waterford TARA T25 Direct Vent Freestanding Gas Stove
13
INSTALLATION
VERTICAL TERMINATION WITH
CO-LINEAR FLEX SYSTEM
This appliance is designed to be attached to
two 3" (76mm) co-linear aluminium flex running
the full length of the chimney. The flue length
must be a minimum length of 8 ' (2.44m) and a
maximum of 35' (10.7m). See chart for minimum
distances from roof. Periodically check that the
vent is unrestricted.
Masonry chimneys may take
various contours which the
flexible liner will accommo-
date. However, keep the
flexible liner as straight
as possible, avoid unnec-
essary bending.
The Air Intake pipe must be attached to the inlet
air collar of the termination cap.
Diagram 5
c) Before connecting the vent pipe to the vent
termination, slide the black decorative wall
thimble cover over the vent pipe, then slide
the Wall Penetration Heat Shield (Part #
946-202) over the vent pipe. Dia. 3.
d) Slide the appliance and vent assembly
towards the wall carefully inserting the
vent pipe into the riser vent terminal assem-
bly. It is important that the vent pipe extends
into the Riser Vent Backing Plate a suffi-
cient distance so as to result in a minimum
pipe overlap of 1-1/4 inches. Secure the
connection between the vent pipe and the
vent cap by attaching the two sheet metal
strips extending from the Riser Vent Back-
ing Plate into the outer wall of the vent pipe.
Use two aluminum screws provided to
connect the strips to the pipe section. Bend
any remaining portion of the sheet metal
strip back towards the vent cap and cut off
any excess, it will be concealed by the
decorative wall thimble cover. See diagram
5.
8) Slide the decorative wall thimble up to the
wall surface being careful not to scratch
the paint. See diagram 5.
9) Back outside: Apply sealant to the 4" inner
flue and slide the Riser Vent Front into the
Backing Plate and fasten with 8 screws.
IMPORTANT:
When connecting the pipe to the Riser
Vent, apply Mill-Pac to the inner pipe
on the Riser Vent Terminal, around
the bead. Ensure
that the vent pipe is
pushed past the
bead for a secure fit.
10)Seal around the outer edge of the Riser
Vent Backing Plate.
Required Parts:
Part # Description
945G 45
o
Elbow
946-529 Co-linear DV Vertical
Termination Cap
948-305 3" Flex - 35 ft.
270-944 U27 Dura-Vent Adapter
946-563 Co-Axial to Co-Linear
Adapter Kit which
contains the following:
Co-linear Flex Adapter (270-585)
Outer Pipe (946-257)
Inner Pipe Adapter (946-219)
Alternate Approved Caps
980 Vertical Termination Cap
991 High Wind Cap
923GK 3" Co-linear Adapter
with flashing
THE APPLIANCE MUST NOT BE
CONNECTED TO A CHIMNEY FLUE
SERVING A SEPARATE SOLID FUEL
BURNING APPLIANCE.