Viper VR-6000 Air Conditioner User Manual


 
INSTRUCTIO NS MANUAL
MAINTENANCE
REPLACING REFRIGERANT FILT ER/DRYER
The VIPER VR-6000 is equipped with two high side refrigerant filters/dryers and a low side
refrigerantfilter/dryer (see figure 14). In order to m aintain high qualityrecycled refrigerant:
The low side refrigerant filter/dryer must be changed when the VR-6000 displays the
service alarm [SERV]and the led “REPLACE FILTER”lights up.
NOTE: When recovering new refrigerantas when the machine is firs t placed in s ervice
this alarm will light abnormally early and may be cleared by press ing the “SEL” key
while turning on the machine.
The high-press ure refrigerant filters/dryers must be replaced after approxim ately 30
hours ofoperation or 150 service jobs .
ATTENTION: Use only Clore Automotive Filters Part No. 315-032-000 (Low )
andPart No.315-035-666 (High).
When changing the high pres sure filters it is recomm ended that you disconnect the liquid
hose from the s torage tank (clos e the hose valve and the liquid tank valve firs t), and recover
the refrigerant from the machine with another machine through the liquid hose. Then
proceed as described below:
2
3
1
Fig.14:Dryer filters
20