9PKG-PRC010-EN
Selection
Procedure
A 1 0 1 0 0 A 0 B 0 0 2 0 2 A 1 0 0
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
Self-Contained Accessory Model Number Description
Digit 1 - Discharge Plenum
A = 3 Ton Standard Plenum
B = 3 Ton Protective Coated Plenum
C = 5 Ton Standard Plenum
D = 5 Ton Protective Coated Plenum
E = 7.5 Ton Standard Plenum
F = 7.5 Ton Protective Coated Plenum
G = 10 Ton Standard Plenum
H = 10 Ton Protective Coated Plenum
I = 15 Ton Standard Plenum
J = 15 Ton Protective Coated Plenum
0 = None
Digit 2 - Permanent Filters
1 = 3 Ton (1) 20 x 25 x 1
2 = 5 Ton (2) 16 x 25 x 1
3 = 7.5 Ton (4) 15 x 20 x 1
4 = 10 Ton (3) 20 x 25 x 2
5 = 15 Ton (8) 15 x 20 x 2
0 = None
Digit 3 - Front Return Air Grille
A = 10 Ton Front Return Air Grille
B = 10 Ton Protective Coated Front Rtn
Air Grille
C = 15 Ton Front Return Air Grille
D = 15 Ton Protective Coated Front Rtn
Air Grille
0 = None
Digit 4 - Rubber-In-Shear Isolators
1 = 3 Ton Isolators
2 = 5 Ton Isolators
3 = 7.5 Ton Isolators
4 = 10 Ton Standard Configuration
Isolators
5 = 10 Ton Horz. Inverted “L” Isolators
(Air-Cooled Units Only)
6 = 10 Ton Horz. Inverted “L” Isolators
(Water-Cooled Units Only)
7 = 15 Ton Standard Configuration
Isolators
8 = 15 Ton Horz. Inverted “L” Isolators
(Air and Water-Cooled Units)
0 = None
Digit 5 - Steel Spring Isolators
A = 3 Ton Isolators
B = 5 Ton Isolators
C = 7.5 Ton Isolators
D = 10 Ton Standard Configuration
Isolators (Air-Cooled Units Only)
E = 10 Ton Standard Configuration
Isolators (Water-Cooled Units Only)
F = 10 Ton Horz. Inverted “L” Isolators
(Air and Water-Cooled Units)
G = 15 Ton Standard Configuration
Isolators
H = 15 Ton Horz. Inverted “L” Isolators
(Air and Water Cooled Units)
0 = None
Digit 6 - Unit Mounted Thermostat
1 = 10 & 15 Ton 2 Cool Thermostat
2 = 3, 5, & 7.5 Ton 2 Cool Thermostat
0 = None
Digit 7 - Remote Mounted Thermostat
A = 3, 5, & 7.5 Ton 0H/2C (Auto)
B = 10 & 15 Ton 2H/2C (Manual)
C = 10 & 15 Ton 2H/2C (Auto)
0 = None
Digit 8 - Programmable Night Setback
Thermostat
1 = 3, 5, & 7.5 Ton 1H/2C
2 = 10 & 15 Ton 2H/2C
0 = None
Digit 9 - Fan Motor Kits (Includes Drives)
A = 3 Ton,
3
/
4
HP, 208-230 Volt
B = 3 Ton,
3
/
4
HP, 460 Volt
C = 5 Ton, 1 HP, 208-230 Volt
D = 5 Ton, 1 HP, 460 Volt
E = 5 Ton, 1-
1
/
2
HP, 208-230 Volt
F = 5 Ton, 1-
1
/
2
HP, 460 Volt
G = 7.5 Ton, 1-
1
/
2
HP, 208-230 & 460 Volt
0 = None
Digit 10 - Oversize Fan Motor Kits
1 = 10 Ton, 3 HP, 208-230 & 460 Volt
2 = 15 Ton, 5 HP, 208-230 & 460 Volt
0 = None
Digit 11 - Accessory Drive Kits
A = 10 Ton, Underspeed Drive Kit
B = 15 Ton, Underspeed Drive Kit
C = 10 & 15 Ton, Overspeed Drive Kit
D = 15 Ton, Extra Overspeed Drive Kit
0 = None
Digit 12 - Hot Water Heating Coil
1=3 Ton
2 = 3 Ton with Corrosion Protection
3=5 Ton
4 = 5 Ton with Corrosion Protection
5 = 7.5 Ton
6 = 7.5 Ton with Corrosion Protection
7 = 10 Ton
8 = 10 Ton with Corrosion Protection
9 = 15 Ton
A = 15 Ton with Corrosion Protection
0 = None
Digit 13 - Steam Heating Coil
A=3 Ton
B = 3 Ton with Corrosion Protection
C=5 Ton
D = 5 Ton with Corrosion Protection
E = 7.5 Ton
F = 7.5 Ton with Corrosion Protection
G = 10 Ton
H = 10 Ton with Corrosion Protecton
I = 15 Ton
J = 15 Ton with Corrosion Protection
0 = None
Digit 14 - 90/10 Cupronickel Condensers
1 = 3 Ton CuNi Condenser
2 = 3 Ton CuNi Protective Coated
Condenser
3 = 5 Ton CuNi Condenser
4 = 5 Ton CuNi Protective Coated
Condenser
5 = 7.5 Ton CuNi Condenser
6 = 7.5 Ton CuNi Protective Coated
Condenser
7 = 10 Ton CuNi Condenser
8 = 10 Ton CuNi Protective Coated
Condenser
9 = 15 Ton CuNi Condenser
A = 15 Ton CuNi Protective Coated
Condenser
Digit 15 - Water Regulating Valve Kit
A = 3 Ton Water Reg. Valve Kit
B = 5 & 7.5 Ton Water Reg. Valve Kit
C = 10 & 15 Ton Water Reg. Valve Kit
Digit 16 - Anti-Recycle Timer
1 = Anti-Recycle Timer
0 = None
Digit 17 - Time Delay Relay
1 = 10 & 15 Ton Time Delay Relay
0 = None
Digit 18 -Low Ambient Damper
A = 3 & 5 Ton Low Ambient Damper
B = 7.5 Ton Low Ambient Damper
C = 10 Ton Low Ambient Damper
D = 15 Ton Low Ambient Damper
0 = None
Model Number
Description