Toshiba RAV-SM1402CT-E Air Conditioner User Manual


 
114
6. External View of P.C. Board
7. Address Setup
In addition to set up the central control address, it is necessary to change the indoor unit number.
(Line/Indoor/Group address).
For details, refer to TCC-LINK Adapter Installation Manual.
12-3. How to set up central control address number
When connecting the indoor unit to the central control remote controller using TCC-LINK adapter, it is neces-
sary to set up the central control address number.
The central control address number is displayed as the line No. of the central control remote controller.
1. Setup from remote controller at indoor unit side
* If you use the network adapter P.C. board, it is effective only when No. 7 of setup switch SW01 on P.C.
board is turned off.
<Procedure> Perform setup wh ile th e unit stops.
1 Push
TEST
+
VENT
buttons for 4 seconds or more.
When group control is executed, first the unit No. RLL is displayed and all the indoor units in the group
control are selected. In this time, fans of all the selected indoor units are turned on. (Fig. 1)
(Keep RLL displayed status without pushing
UNIT
button.)
In case of individual remote controller which is not group-controlled, Line address and Indoor unit address
are displayed.
2 Using temperature setup
TEMP.
buttons, specify item code 03.
3 Using timer time
TIME
buttons, select th e setup data. Th e setup data is sh own in th e righ t
table (Table 1).
4 Push
SET
button. (OK if display goes on.)
To change the item to be set up, return to Procedure 2.
5 Push
TEST
button.
The status returns to usual stop status.
5
2
1
1
3
4
ON / OFF
FAN
TEMP.
SWING/FIXTIME
MODE
VENT
UNITSET CL
FILTER
RESET
TEST
TIMER SET
UNIT No.
DATA
SET
R.C. No.
(Table 1)
Setup data
0001
0002
0003
:
0064
0099
Central control address No.
1
2
3
:
64
Unset (Setup at shipment from factory)
(Fig.1)
Terminator (SW01)
52
85