Toshiba RAS-B10SKVP-E Air Conditioner User Manual


 
– 39 –
Filter lamp ON
Push RESET button.
Did you push [RESET] button
for 3 seconds or more?
Did you push [RESET] button
for 10 seconds or more?
Switch to [AUTO RESTART] control.
YES
YES
NO
NO
NO
YES
Temporary [AUTO] operation
Temporary [COOL] Operation
Sending air purifier-ON
Operation lamp ON
Fan ON
Air purifier ON
Air purifying operation
Start of air purifier-ON
Operation lamp OFF Filter-OFF
Memory position
of louver/COOL
Air conditioner +
air purifier operate
Fan stop
Air purifier-OFF
Louver close
All stop
Air conditioner operates
Sending air purifier-OFF
1
,
2
3
1 2
3 4
,
4
Air conditioner operatesAir conditioner stops
Air purifier operates Air conditioner +
Air purifier operate
*1
*2
Item
11. Temporary
operation
12. Air
purifying
control
Operation flow and applicable data, etc.
Pushing [RESET] button starts the temporary operation
of [AUTO] operation. When keeping [RESET] button
pushed for 10 seconds or more, the temporary [COOL]
operation is performed.
This function generates nagative ion while cleaning the air in the room.
If air purifier-ON signal is received while the air conditioner stops, the air purifier starts operation, and if
it is received while the air conditioner operates, the air conditioner and the air purifier start operation.
The air ion generator operates linked with the air purifying operation.
Description
1) When pushing [RESET] button, the
temporary [AUTO] operation starts.
2) When keeping [RESET] button pushed for
3 seconds or more, Pi, Pi, Pi sound is
heard and [AUTO RESTART] control is
changed.
3) When keeping [RESET] button pushed for
10 seconds or more, Pi sound is heard
and the temporary [COOL] operation
starts.
4) If the filter lamp goes on, push [RESET]
button to go off the filter lamp, and then
push [RESET] button again.
5) To stop the temporary operation, push the
button again.
* When the previous operation was the
operation of air conditioner + air purifier,
an operation of air conditioner + air purifier
starts by pushing AC button on the remote
controller.
(Operation of air conditioner + air purifier is
stored in memory.)
*1 Swing is available
*2 Fan speed is Fan Auto mode varies in
order, (M + 1) (L) (L) (SL).
Present status
Stop
Air purifier only
Air conditioner
Joint use of AC and air purifier
Operation button
PURE button Air conditioner
Air purifier AC operation*
Stop (All) AC + Air purifier
AC + Air purifier All stop
AC operation All stop
Air purifying operation
AC + Air purifying operation
Louver*1
Cooling position
Follows to AC operation
Fan speed *2
AUTO, L, L+, M, M+, H
Follows to AC operation