– 103 –
Valve fixing plate
Partition board
Compressor
Reactor
No.
Part name
Compressor
Reactor
Procedure
1) Perform work of item 1 of
and
,
,
,
.
2) Extract refrigerant gas.
3) Remove the partition board.
(ST1TØ4 × 8L 3 pcs.)
4) Remove the sound-insulation material.
5) Remove terminal cover of the compressor, and
disconnect lead wire of the compressor from the
terminal.
6) Remove pipe connected to the compressor with
a burner.
• Take care to keep the 4-way valve away from
naked flames. (Otherwise, it may malfunction.)
7) Remove the fixing screw of the bottom plate
and heat exchanger. (ST1TØ4 × 8L 1 pc.)
8) Remove the fixing screw of the bottom plate
and valve fixing plate. (ST1TØ4 × 8L 1 pc.)
9) Pull upward the refrigeration cycle.
10) Remove BOLT (3 pcs.) fixing the compressor
to the bottom plate.
* Precautions when assembling the compressor.
Tighten the compressor bolts using a tighten-
ing torque of 4.9 N•m.
1) Perform work of item 1 of
, and
.
2) Remove screws fixing the reactor.
(ST1TØ4 × 8L 4 pcs.)
Remarks