WARNING:
If you do not follow these instructions exactly, a fire or explosion may result with property damage,
personal injury, or loss of life.
LIGHTING CONTINUOUS PILOT INSTRUCTIONS
Honeywell VR8200
Natural or Propane Gas
A. BEFORE OPERATING smell all around the appliance
area for gas. Be sure to smell next to the floor because
some gas is heavier than air and will settle on the floor.
What to do if you smell gas:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Immediately call your gas supplier from a neighbor's
phone. Follow the gas suppliers instructions.
If you cannot reach your gas supplier, call the fire
department.
B. Use only your hand to push in or turn the gas control
knob, never use tools. If the knob will not push in or turn
by hand dont try to repair it, call a qualified service tech-
nician. Force or attempted repair may result in a fire or
explosion.
C. Do not use this appliance if any part has been under
water. Immediately call a qualified service technician to
inspect the appliance and to replace any part of the con-
trol system and any gas control which has been under
water.
1. STOP! Read the safety information above.
2. Set the thermostat to lowest setting.
3. Turn off all electric power to the appliance.
4. Remove control access panel (if applicable).
5. Rotate gas control knob clockwise to OFF.
6. Wait five (5) minutes to clear out any gas. Then smell for
gas, including near the floor. If you then smell gas STOP!
Follow A in the safety information above. If you dont
smell gas, go to next step.
7. Remove the pilot access panel located below and behind
the gas control unit (if applicable).
8. Find pilot - follow metal tube from gas control. The pilot is
between the two burner tubes behind the pilot access
panel (if applicable).
9. Turn gas control knob counterclockwise to PILOT.
10. Push down and hold the red button next to the control
knob. Immediately light the pilot with a match. Continue
to hold the red button down for about one (1) minute after
the pilot is lit. Release button and it will pop back up. Pilot
should remain lit. If it goes out, repeat steps 5 through
10.
If button does not pop up when released, stop and
immediately call your service technician or gas suppli-
er.
If the pilot will not stay lit after several tries, turn the
gas control knob to "OFF" and call your service tech-
nician or gas supplier.
INLET
GAS CONTROL KNOB
SHOWN IN "OFF" POSITION
GAS
ON
OFF
RESET BUTTON
PILOT
CONTINUOUS PILOT - HONEYWELL VR8200
11. Replace pilot access panel.
12. Turn gas control knob counterclockwise to "ON".
13. Replace control access panel (if applicable).