Sierra Monitor Corporation IZS30 SERIES Air Cleaner User Manual


 
WARNING
1. Check that power supply capacity is enough and voltage is in specification before piping.
2. Apply type D earthing to prevent electrical shock in accordance with instructions on this operation
manual.
3. Be sure to cut off power supply at wiring (inclu/ding connector plug-in/out) .
4. Use special cable for the connection between body and sensor, and disassembly and reconstruction
are prohibited.
5. Turn on the power after examining wiring and a surrounding situation enough, and confirming safety.
6. Do not connect and disconnect connectors while supplying the power
7. Installation with high-voltage line and power line in the same wiring route may cause malfunction by
noise. Install separately with them.
8. Be sure there is no incorrect wiring before operation. Incorrect wiring may cause product breakage or
malfunction.
9. Flush pneumatic piping before its installation. Make sure that all dust, water droplet, oil etc. are
eliminated before piping.
WARNING
1. Use within operating fluid and ambient temperature range.
Operating fluid and ambient temperature range for Ionizer and sensor are 0 to 50
o
C. When temp. is
5
o
C or less, take measure to prevent freezing. Though ambient temperature is within specification,
dew condensation might be generated where temperature is suddenly changed. Therefore do not use
under such environment.
2. Environment to avoid
Do not use or store under the following environments, as these may cause operation failure. If it is
unavoidable, take the appropriate measures.
a. The place where ambient temperature exceeds 0 to 5
o
C.
b. The place where ambient humidity exceeds 35 to 85% RH.
c. The place where dew condensation is generated due to sudden temperature change.
d. The place where there is corrosive gas, inflammable gas, and volatile inflammable substance is
stored.
e. The atmosphere where the product is exposed to conductive powder such as iron powder and dust, oil
mist, salt and organic solvent or machining chips, particles and cutting oil (water, liquid).
f. The place where product is directly exposed to the blow from air-conditioners.
g. The place where sealed and ventilation is not installed.
h. The place the product is exposed to the direct sunlight and radiant heat.
i. The place where strong electromagnetic noise is generated. (Strong electric field/ strong magnetic
field/ surge.)
j. The place where electricity is discharged. The situation which causes electric discharge on the
Wiring and piping
Environment
200
200
(mm)
150
150