4
(3) Indoor unit KHS1852
Outdoor unit CH1852
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Remarks: Rating conditions are
Cooling: Indoor air temperature 80°F D.B. / 67°F W.B.
Outdoor air temperature 95°F D.B. / 75°F W.B.
Heating: Indoor air temperature 70°F D.B.
Outdoor air temperature 47°F D.B. / 43°F W.B.
Features
Controls / Temperature control Microprocessor / I.C. thermostat
Control unit Wireless remote control unit
Timer ON / OFF 12 hours, 1-hour OFF
Fan speeds Indoor / Outdoor 3 and Auto / 1 (Hi)
Airflow direction (Indoor) Horizontal Manual
Vertical Auto
Air filter Washable
Compressor Rotary (Hermetic)
Refrigerant / Amount charged at shipment lb. (kg) 3.97 (1.80)
Refrigerant control Capillary tube
Operation sound Indoor: Hi / Me / Lo dB-A 41 / 38 / 36
Outdoor: Hi dB-A 52
Refrigerant tubing connections Flare
Max allowable tubing length at shipment ft. (m) 25 (7.5)
Refrigerant tubing Narrow tube inch (mm) 1/4 (6.35)
diameter
Wide tube inch (mm) 5/8 (15.88)
Dimensions & Weight Indoor Unit Outdoor Unit
Unit dimensions Height inch (mm) 11-7/32 (285) 24-19/32 (625)
Width inch (mm) 39-3/16 (995) 34-21/32 (880)
Depth inch (mm) 7-23/32 (196) 12-19/32 (320)
Package dimensions Height inch (mm) 10-7/8 (276) 27-15/16 (710)
Width inch (mm) 42-1/8 (1,070) 40-9/16 (1,030)
Depth inch (mm) 14-9/32 (363) 16-3/16 (411)
Weight Net lb. (kg) 26.5 (12.0) 108 (49)
Shipping lb. (kg) 33 (15.0) 117 (53)
Shipping volume cu.ft (m
3
) 3.78 (0.107) 10.6 (0.301)
Performance Cooling Heating
Capacity BTU/h 17,000 / 16,500 19,000 / 18,500
kW 4.98 / 4.84 5.75 / 5.42
Air circulation (High) ft
3
/min (m
3
/min) 390 (11.1)
Moisture removal (High) Pints/h 4.5 / 4.3 —
Electrical Rating Cooling Heating
Available voltage range V 187 – 253
Running amperes A 7.6 / 8.1 7.1 / 7.5
Power input W 1,700 / 1,660 1,610 / 1,540
Power factor % 99 99
SEER (HSPF) BTU/W 10.5 (6.8)
Compressor locked rotor amperes A 43
Heater element kW —
Cooling Heating
Voltage Rating 230 / 208V 60Hz
000-111 SM (1-17) 00.3.17 11:44 AM y[W 4