Sanyo KHS1852 Air Conditioner User Manual


 
29
Outdoor temperature (¡F DB)
0
10
20
30
40
50
60
70
80
90
100
110
120
Heating capacity ratio (%)
47 50 6040302017
5-4. Heating Capacity
Indoor unit KHS0951 / KHS1251 / KHS1852
Outdoor unit CH0951 / CH1251 / CH1852
1)
Point of rating condition
Black dot in the chart indicates the following rating condition.
Indoor: 70°F (21.1°C) D.B.
Outdoor: 47°F (8.3°C) D.B. / 43°F (6.1°C) W.B.
2) Above characteristics indicate instantaneous operation, which does not take into account defrost
operation.
3) Fan speed: High
4) Because this air conditioner heats a room by drawing in the heat of the outside air (heat pump system),
the heating efficiency will fall off when the outdoor temperature is very low. If sufficient heat cannot be
obtained with this air conditioner, use another heating appliance in conjunction with it.
NOTE
000-111 SM (18-68) 00.3.17 11:49 AM y[W 29