Sanyo KHS1852 Air Conditioner User Manual


 
54
9. TROUBLESHOOTING
9-1. Check before and after troubleshooting
9-1-1. Check power supply wiring.
Check that power supply wires are correctly connected to terminals No. 7 (L1) and No. 8 (L2) on the terminal
plate in the outdoor unit.
9-1-2. Check inter-unit wiring.
Check that inter-unit wiring is correctly connected to the indoor unit from the outdoor unit.
9-1-3. Check power supply.
Check that voltage is in specified range (±10% of the rating).
Check that power is being supplied.
9-1-4. Check lead wires and connectors in indoor and outdoor units.
Check that coating of lead wires is not damaged.
Check that lead wires and connectors are firmly connected.
Check that wiring is correct.
1
2
4
5
6
8
1
2
3
4
5
6
Indoor
unit
Outdoor
unit
Inter–unit
power wiring
Inter–unit
control wiring
7
Power supply :
Single- phase, 60Hz
115V.....CH0951,CH1251
230/208V............CH1852
3
G
Ground
G
Ground
G
L1
L2
WARNING
Hazardous voltage can cause ELECTRIC SHOCK or
DEATH. Disconnect power or turn off circuit breaker
before you start checking or servicing.
000-111 SM (18-68) 00.3.17 11:49 AM y[W 54