Remington QFP40 Indoor Fireplace User Manual


 
Page 53
REMINGTON QFP40 Direct Vent FIREPLACE
250-4721 JUNE 2001
All arched and rectangular fascia attach to four flanges located two to each side of the
glass frame. Insert and finger start bolts tightening with the 5/32" Allen wrench supplied with
unit.
INSTALLING GLASS
The glass assembly has a narrow metal edge at top of the frame, and wide metal edge at
bottom of the frame. To install the glass assembly, lift and set the bottom T-bar extensions onto
the bottom alignment pins located at the edge of firebox--refer to diagram below. With the
bottom edge of glass assembly resting on the bottom alignment pins, lift up and onto the top
alignment pins. Secure the assembly to zc appliance with the spring latches, two on top and two
at bottom.
GLASS & FASCIA
Flanges for fas-
cia attachment,
and T-bar exten-
sions for setting
glass onto align-
ment pins.
(2 per side)
Alignment pins.
(2 per side)
Spring Latches.
(2 upper & 2 lower)
INSTALLING FASCIA
Insert bolts through
these holes and into
Flanges shown in
picture above. (2 per
side)
T-bar extension
of Flange.
Narrow Edge (TOP)
Wide Edge (BOTTOM)
WARNING: Use care in handling of glass assembly, do not strike or slam as this
could cause breakage.