Remington QFP40 Indoor Fireplace User Manual


 
REMINGTON QFP40 Direct Vent FIREPLACE
Page 14
250-4721 JUNE 2001
NOTE: If converting this unit to propane, do so at this point of installation.
LP CONVERSION INSTRUCTIONS
Part # 842-4470 is required for this procedure.
CAUTION: DISCONNECT ANY ELECTRICAL CORDS AND TURN OFF
GAS SUPPLY TO UNIT BEFORE PROCEEDING.
Valve Regulator Tower
1. Turn control knob to the OFF position and shut off the gas supply to the valve.
2. Using a Torx TH20, or slotted screwdriver, remove the three pressure regulator
mounting screws (A), pressure regulator tower (B), and diaphragm (C). (You may
wish to retain these items for converting back to original gas if necessary.)
3. Insure that the rubber gasket (D) is properly positioned and install the new HI/LO
pressure regulator assembly to the valve using the new screws (E) supplied with
the kit. Tighten screws securely. (Reference torque = 25 in/lb)
4. Install the enclosed identification label (F) to the valve body where it can be seen.
WARNING !
The installation of this conversion kit must only be undertaken by a quali-
fied and certified gas appliance installer.
LP CONVERSION
A
B
C
E
D
F