Remington QFP40 Indoor Fireplace User Manual


 
REMINGTON QFP40 Direct Vent FIREPLACE
Page 44
250-4721 JUNE 2001
Step 5. Connect the flex liner to the top adapter
using three sheet metal screws (see Fig-
ure 19, page 42).
Step 6. Feed the flex liner through the flashing
into the chimney. Carefully feed the flex
liner down the chimney to the bottom and
out the opening in the masonry wall,
forming an angle to line up the flex liner
with the vent opening on the appliance.
WARNING: Do not let the flex liner
sag below the level at which it will
connect to the appliance or connec-
tor. This could allow hot gas to be-
come trapped and potentially become
a fire hazard. The flex liner path
should always be sloped up toward
the termination cap.
Step 7. If additional lengths of flex liner are
needed to span the chimney height, use
a flex coupler to connect the pieces of
flex liner together. Connect the flex to
the coupler by using four sheet metal
screws for each side (Figure 24).
Step 8. Secure the top adapter to the flashing.
Use three sheet metal screws through
the side of the top adapter into the flange
on the flashing (Figure 25). Twist lock
the high wind termination cap (SDV
#991) on to the top adapter.
FIG. 24
FIG. 25