Regency Z2510L Indoor Fireplace User Manual


 
Regency Z2510 WarmHearth 9
Ventilated Chase Pan
In Canada:
Any factory built chimney listed and certifi ed to
ULC-S629. Also any of the following chimney
covered by ULC-S610 or ULC S604.
1) GSW Heating Products Model JFC
2) Oliver McLeod Ltd. Model PRO-JET3103
3) Security Chimney Ltd. Model ASHT
4) Selkirk Metalbestos Model SS
5) ICC Excel 103 HT
6) ICC Excel 2100
In U.S.A.
Any of the following chimney systems covered
by UL-103HT may be used.
1) American Metal Product AMERI-TEC
Model HS
2) GSW Heating Products Model FC
3) Oliver McLeod Ltd. Model PRO-JET3103
4) Security Chimney Ltd. Model ASHT
5) Security Chimney Ltd. Model S2100
6) Security Chimney Ltd. Model Sentinel
7) Selkirk Metalbestos Model SS II
8) Simpson Dura-Vent Model Dura-Plus
9) ICC Excel 103 HT
10) ICC Excel 2100
Note: Anchor Plate/Fireplace Adaptor must
be purchased with Chimney system.
The use of only one of these systems is permitted
when installing the WarmHearth. Do not alter
or mix parts from other systems as this may
cause a potential hazard and void Regency’s
limited warranty.
INSTALLATION
support as well as the fl oor beneath the
hearth extension.
Note: The “Z” type safety strip is not
supplied by Regency and must be
fabricated locally.
2) Refer to fi replace Dimensions and Specifi -
cations section for framing dimensions and
details. The framing header may be posi-
tioned directly on top of the front fi replace
stand-offs.
IMPORTANT: Under no circum-
stances can the fi replace top or side
spacers be removed or modifi ed. Do
not notch the header to be installed
closer than the fi replace outside
facing spacers.
3) Fireplace must be anchored to the framing
to prevent movement or rocking; use wall
grips or seismic brackets which have been
supplied. These angle brackets are installed
by attaching them to the side of the unit and
to the back side of the 2 x 4 or further back
on 2 x 6 framing.
CHIMNEY SYSTEM
CONSIDERATIONS
Regency’s WarmHearth Fireplace is to be
installed with one of the following Chimney
Systems only. Chimney systems going from 7
in. to 8 in. diameter (with adaptor #000-924)
may be used.
Chimney Height
The total height of your WarmHearth fi replace
system from the surface the fi replace rests on
to the chimney top must not exceed 36 ft. and
must also meet minimum system height chart.
Please refer to the Flue Manufacturer's Instruc-
tions for specifi c details (refer to the Minimum
Flue System Heights section).
Chase Enclosure
A chase is a vertical box-like structure con-
structed to surround the fi replace and chimney.
A ventilated chase cap is highly recommended.
Refer to fl ue manufacturer's instructions for
reduced fl ue heights above chase terminations.
ICC and Dura-Vent allow for reduced height with
ventilated chase fl ashing. As with all chimney
installations, avoid overhead obstructions such
as trees, power lines, etc.
A chase should be constructed just like any
outside wall. In a cold climate, we recommend
the base of the chase be insulated between the
solid continuous fl oor beneath the fi replace and
the chase bottom. If used, the value and amount
of chase insulation in a cold climate installation
is optional and not required for safety. Insulation
is recommended to avoid heat loss.
Note: Insulation does not come in contact with
Chimney. Maintain a 2 in. clearance.