Regency Z2510L Indoor Fireplace User Manual


 
Regency Z2510 WarmHearth10
INSTALLATION
ASSEMBLY STEPS
Note: The following steps represent the nor-
mal sequence of installation. Each
installation is unique, however, and
might require different steps. Each
step is dealt with in detail in the fol-
lowing pages.
1) Install stand-offs and insulation strip to the
unit (refer to the Installation Components
Diagram).
2) Complete Framing for the WarmHearth (refer
to the Framing section).
IMPORTANT: Remove all gold accesso-
ries such as door, louvers while installing
to avoid marking.
Position fi rebox prior to framing or into pre-
pared framing (refer to the Framing Details
section).
3) Install the chimney system (refer to the
Chimney System Considerations section).
4) Install outside combustion air kit (refer to
Installing the Outside Air Kit section).
5) Hook-up the Wiring (see Wiring the Warm-
Hearth section).
6) Install the Blowers (refer to the Installing the
Blower Systems).
7) Gravity Air Feed Option (refer to the Gravity
Air Feed Kit Option).
8) Install Central Heat Kit, if applicable (refer to
the Installing Your Central Heating System
section).
9) Complete fi nish wall material, surround and
hearth extension to your individual taste (
refer to the Finishing the WarmHearth).
10) Position masonry liner/bricks and ceramic
fi ber insulation in the unit. Attach gold lou-
vers, glass, door, spring handles (refer to
the Masonry Liner / Bricks section).
INSTALLING THE
STAND-OFFS
Stand-offs are installed to provide reduced
temperatures and proper clearances for the
safe installation of your product. They consist
of four 1 in. stand-offs on the back, two 2 in.
stand-offs on each side and one 6 in. stand-off
on the top of the unit.
Attach these stand-offs where indicated in the
pre-drilled holes on the unit body.
BEFORE YOU START
Check your inventory list to be sure you have all the necessary parts supplied in good usable
condition. Check for any concealed damage. Check the operation of the combustion air damper.
When the damper is in the fully closed position, the damper handle should be to the right. When
damper is in the fully open position, the damper handle must be in the left position.
Installation Components