25) Locate the ground lug at the receptical
box, left of the unit.
Installer Notice:
These instructions must be left
with the appliance.
26) Connect one end of the supplied green
ground wire to the lug with the nut and
washer from the kit.
27) Install the 1/2" bushing to the heat shield.
Ground
wire from
kit
29) Plug the DC spark generator wires to the
DC Sparker.
30) Connect the ground wire to the DC
Sparker mounting bracket.
32) Mount the heat shield to the DC Sparker.
Secure into place with the velcro, which is
provided in the kit.
34) Tie up the loose wire with the wire clip.
Heat Shield
28) Run the other end of the ground wire and
DC spark generator wires through the
bushing on the heat shield.
33) Find a location which is not too hot and is
easy to reach for changing the
battery.
35) Check for gas leaks.
36) Check inlet and outlet pressures.
37) Check operation of fl ame control.
38) Check for proper fl ame appearance and
glow on logs.
31) Install the supplied battery into the DC Sparker
Box by opening the battery compartment.
NOTE: The battery in the DC Sparker Box
will need to be replaced annually.
Battery
Compartment
INSTALLATION