Regency P121 Indoor Fireplace User Manual


 
Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace
8
LOCATING YOUR
GAS FIREPLACE
1) When selecting a location for your stove,
ensure that the clearances are met as
outlined on page 9.
2) Provide adequate clearances for servic-
ing.
3) The appliance must be installed on a flat,
solid, continuous surface (e.g. wood, met-
al, concrete). This may be the floor, or
raised up on a platform to enhance its
visual impact. If the appliance is going to be
installed on carpeting, combustible linole-
um tile or other combustible material other
than wood flooring, the appliance must be
installed on a metal or wood panel extend-
ing the full width and depth of the appli-
ance.
4) The Direct Vent Gas Fireplace can be
installed as follows:
Model # Position
A) P121-1: See Thru
B) P131-1: Pier
C) P121LC-1: Left Corner
D) P121RC-1: Right Corner
5) This appliance is Listed for bedroom instal-
lations when used with a Listed Millivolt
Thermostat. Some areas may have further
requirements, check local codes before
installation.
6) The P121-1/P121LC-1/P121RC-1/P131-1
Direct Vent Gas Fireplace is approved for
alcove installations, which meet the clear-
ances listed on this page.
7) We recommend that you plan your instal-
lation on paper using exact measurements
for clearances and floor protection before
actually installing this appliance. Have a
qualified inspector, dealer, or installer re-
view your plans before installation.
Note: For Exterior Vent Termination
Locations see page 12.
.
INSTALLATION
A) P121-1 See Thru
B) P131-1 Pier
C) P121LC-1 Left Corner
D) P121RC-1 Right Corner