MAINTENANCE
INSTRUCTIONS
1) Always turn off the gas valve before
cleaning. For relighting, refer to lighting
instructions. Keep the burner and control
compartment clean by brushing and vacu-
uming at least once a year. When cleaning
the logs, use a soft clean paint brush as the
logs are fragile and easily damaged.
2) Clean appliance and door with a damp cloth
(never when unit is hot). Never use an
abrasive cleaner. The glass should be
cleaned with a gas fireplace glass cleaner.
The glass should be cleaned when it
starts looking cloudy.
3) The heater is finished in a heat resistant
paint and should only be refinished with
heat resistant paint. Regency uses Stove-
Bright Paint - Metallic Black #6309.
4) Make a periodic check of burner for proper
position and condition. Visually check the
flame of the burner periodically, making
sure the flames are steady; not lifting or
floating. If there is a problem, call a qualified
service person.
5) The appliance and venting system must be
inspected before use, and at least annual-
ly, by a qualified field service person, to
ensure that the flow of combustion and
ventilation air is not obstructed.
Note: Never operate the appliance with-
out the glass properly secured in
place.
6) Do not use this appliance if any part has
been under water. Immediately call a qual-
ified service technician to inspect the ap-
pliance and to replace nay part of the
control system and any gas control which
has been under water.
7) In the event this appliance has been serv-
iced check that the vent-air system has
been properly resealed & reinstalled in
accordance with the manufacturer's in-
structions.
8) Verify operation after servicing.
General Vent Maintenance
Conduct an inspection of the venting system
semi-annually. Recommended areas to inspect
as follows:
1) Check the Venting System for corrosion in
areas that are exposed to the elements.
These will appear as rust spots or streaks,
and in extreme cases, holes. These com-
ponents should be replaced immediately.
Copy of the Lighting Plate Instructions
OPERATING INSTRUCTIONS
Pilot Flame:
While the pilot flame is on it can make a very
slight "whisper" sound.
Gas Control Valve:
As the gas control valve turns ON and OFF, a
dull clicking sound may be audible, this is normal
operation of a gas regulator or valve.
Unit Body/Firebox:
Different types and thicknesses of steel will
expand and contract at different rates resulting
in some "cracking" and "ticking" sounds will be
heard throughout the cycling process.
TO TURN OFF GAS APPLIANCE
FOR YOUR SAFETY READ BEFORE LIGHTING
This appliance must be installed in accordance with local codes, if any; if not, follow
the current CAN1-B149/ANSI Z 223.1 (Australia: AG601, New Zealand: NZS 5261)
4)Push in control knob all the way and
hold in. Continually push and release
the black button on spark igniter until
pilot lights. Continue to hold the
control knob in for about 1/2 minute
after the pilot is lit. Release knob and
it will pop back up. Pilot should remain
lit. If it goes out, repeat steps 1) to 4).
If knob does not pop up when released,
stop and immediately call your service
technician or gas supplier. If the pilot will
not stay lit after several tries, turn the gas
control knob to “OFF” and call your
service technician or gas supplier.
STOP! Read the safety information
above on this label.
1) Push in gas control knob slightly and
turn clockwise to “OFF”. Knob
cannot be turned from “PILOT” to “OFF”
unless knob is pushed in slightly. Do
not force.
2) Wait five (5) minutes to clear out any
gas. If you then smell gas STOP! follow
“B” in the safety information above on
this label. If you don’t smell gas, go to
the next step.
3)Turn knob on gas control counter-
clockwise to“PILOT”.
1) Push in the gas control knob slightly and
turn clockwise to “OFF”. Do not force.
CAUTION: Hot while in operation. Do not touch. Severe Burns may result. Due
to high surface temperatures keep children, clothing and furniture, gasoline
and other liquids having fammable vapors away. Keep burner and control
compartment clean. See installation and operating instructions
accompanying appliance.
LIGHTING INSTRUCTIONS
5)Turn gas control knob
counterclock-wise
to “ON”.
6)Use rocker switch to op-
erate main burner.
A)This appliance has a pilot which
must be lighted by hand. When
lighting the pilot, follow these
instructions exactly.
B)BEFORE LIGHTING smell all around
the appliance area for gas. Be sure to
smell next to the floor because some
gas is heavier than air and will settle
on the floor.
WHAT TO DO IF YOU SMELL GAS
- Do not try to light any appliance
- Do not touch any electric switch, do
not use any phone in your building
- Immediately call your gas supplier
from a neighbours phone. Follow the
gas supplier’s instructions.
- If you cannot reach your gas supplier,
call the fire department.
C)Use only your hand to push in or turn
the gas control knob. Never use tools.
If the knob will not push in or turn by
hand, don’t try to repair it, call a qualified
service technician. Force or attempted
repair may result in a fire or explosion.
D) Do not use this appliance if any part has
been under water. Immediately call a
qualified service technician to inspect the
appliance and to replace any part of the
control system and any gas control which
has been under water.
This appliance needs fresh air for safe
operation and must be installed so there are
provisions for adequate combustion and
ventilation air.
DO NOT REMOVE THIS INSTRUCTION PLATE
WARNING: If you do not follow these instructions exactly, a fire or
explosion may result causing property damage, personal injury or loss
of life. Improper installation, adjustment, alteration, service or maintenance
can cause injury or property damage. Refer to the owner’s information
manual provided with this appliance. For assistance or additional
information consult a qualified installer, service agency or gas supplier.
OFF
ELEMENT
THERMO-
ELECTRIQUE
VEILLEUSE
PILOT BURNER
THERMOPILE
908-017a
2)Turn off all electric power to the
appliance if service is to be performed.
You may shut off the pilot during prolonged non use periods to conserve fuel.