Regency P121 Indoor Fireplace User Manual


 
Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace 31
MAINTENANCE
2) Remove the Cap, and shine a flashlight
down the Vent. Remove any bird nests, or
other foreign material.
3) Check for evidences of excessive con-
densation, such as water droplets forming
in the inner liner, and subsequently dripping
out the joints, Continuous condensation
can cause corrosion of caps, pipe, and
fittings. It may be caused by having exces-
sive lateral runs, too many elbows, and
exterior portions of the system being ex-
posed to cold weather.
4) Inspect joints, to verify that no pipe sections
or fittings have been disturbed, and conse-
quently loosened. Also check mechanical
supports such as Wall Straps, or plumbers'
tape for rigidity.
LOG REPLACEMENT
The unit should never be used with broken logs.
Turn off the gas valve and allow the unit to cool
before opening door and carefully remove the
logs. (The pilot light generates enough heat to
burn someone.) If for any reason a log should
need replacement, you must use the proper
replacement log. The position of these logs
must be as shown in the diagrams under Log
Installation.
Note: Improper positioning of logs may
create carbon build-up and will
severely alter the unit's perform-
ance which is not covered under
warranty.
THERMOPILE/
THERMOCOUPLE
1) Open the Bottom Louvers or Grills. Remove
the Top Louver or Grill.
2) Remove the Trim Kit, Glass Door, Log Set,
Grate and Burner Assembly (see page 26).
3) Disconnect thermocouple by loosening nut
from the valve with a 9mm wrench. Discon-
nect thermopile by loosening 2 screws
marked TP on the valve.
4) Remove 2 screws from the pilot assembly
and pull up far enough to be able to loosen
the thermocouple or thermopile with a 7/16"
wrench. NOTE: the pilot line is very fragile,
use caution when pulling it up.
5) Drop the thermocouple or thermopile down
through the extrusion and pull it out of the
unit.
6) Reinstall the new ones in reverse order.
GLASS GASKET
If the glass gasket requires replacement use
a tadpole glass gasket (Part # 936-155).
DOOR GLASS
Your Regency fireplace is supplied with high
temperature 5mm-Tempered glass & 5mm-Ce-
ramic glass. If your glass requires cleaning, we
recommend using an approved glass cleaner
available at all authorized dealers. Do not use
abrasive materials.
CAUTION & WARNINGS:
* Do not clean when the glass is hot.
* The use of substitute glass will void all product
warranties.
* Care must be taken to avoid breakage of the
glass.
* Do not strike or abuse the glass.
* Do not operate this fireplace without the glass
front or with a cracked or broken glass front.
* Wear gloves when removing damaged or
broken glass.
* Replacement of the glass panels should be
done by a licensed or qualified service per
son.
GLASS REPLACEMENT
In the event that you break your glass by impact,
purchase your replacement from an authorized
Regency dealer only. Replacement glass is
shipped already installed into the door frame.
Reinstall as per Glass Door Installation on page
22.
REPLACEMENT PARTS:
Front Door - Tempered (Part# 360-528)
Side Door - Tempered (Part# 360-529)
Front Door - Ceramic (Part# 360-538)
Side Door - Ceramic (Part# 360-539)
GOLD-PLATED
ACCESSORIES
The 24 carat gold-plated finish requires little
maintenance, and need only be cleaned with a
damp cloth. DO NOT use abrasive materials or
chemical cleaners, as they may harm the finish
and void the warranty. Clean any finger-
prints off before turning the unit on.
REMOVING VALVE
1) Shut off the gas supply.
2) Remove the louvers and trim kit. Remove the
front door.
3) Remove the logs, embers.
4) Remove the grate by lifting straight up.
7) Slide the burner assembly away from the
orifice and lift out.
5) Remove the side brick clip in the top of the
firebox and then slide the Side Brick Panel
out. The brick panels are very fragile
- handle with care.
6) Remove the burner by removing the 4
screws.