Regency P121 Indoor Fireplace User Manual


 
Regency P121-1/P121LC-1/P121RC-1/P131-1 Zero Clearance Direct Vent Gas Fireplace 33
FAN REPLACEMENT
1) Shut off power.
2) Remove top louvers.
3) Unplug power wires.
4) Remove 4 screws securing fan to mounting bracket.
MAINTENANCE
5) Remove 2 connector wires.
6) Replace fan.
7) Repeat for opposite side/corner.
8) Reverse steps 1 - 5 for installation.
9) To remove the thermodisc, located at the back center of the unit, slide
the thermodisc/cover assembly away from the bracket clip on the under
side of the firebox. Reverse for installation. Ensure that no wires will touch
hot surfaces.
Connector wires