Regency I2100M Indoor Fireplace User Manual


 
Regency Insert & Hearth Heater10
Thermo Switch Sensor
Thermo Switch Sensor
INSTALLATION
FAN/BLOWER
Blower/Fan Wiring Diagram
3) Slide the supports into the clips. The tension
holding the clips in place may be adjusted by
increasing or decreasing the offset spacing
of the clips.
4) Ensure that the power cord is not in contact
with any hot stove surfaces.
5) Push the Regency logo plate into the two
holes in the front bottom left corner of the
fan.
Your fan should only be installed once the unit
is in place in order to prevent any damage to the
fan. To attach, follow the instructions provided
with the fan. Make sure to install the rubber
grommet to the fan housing before it is installed
on the insert.
1) Remove the protective covering from the
brass trim on the fan.
2) Align the fan support with the offset clip on
the bottom of the ashlip.
CAUTION: Label all wires prior to
disconnection when servicing con-
trols. Wiring errors can cause im-
proper and dangerous operation.
WARNING:
Electrical Grounding Instructions
This appliance is equipped with a
three pronged (grounding) plug for
your protection against shock haz-
ard and should be plugged directly
into a properly grounded three-prong
receptacle. Do not cut or remove the
grounding prong from this plug.
Do not turn fan ON until your insert has
reached operating temperature or at least
30 minutes after starting fire.