MAINTENANCE
INSTRUCTIONS BELOW FOR HZ54-LP UNIT ONLY.
6) Loosen 6 screws that secure the burner extenders. on burner tray,
located behind the burner on either side of the pilot assembly.
7)
Lift out the 2 burner tray extenders.
8) After extenders have been removed. Remove the 2 screws that
secure the burner tray, at the base of the rebox.
9)
Slide the burner to the left and lift it out.
10) With burner removed - lift out burner tray.
Burner tray extenders
Burner tray extenders
Burner tray
Gas Inlet Line
Burner Bracket
Location of screws securing burner
ON/OFF Connector Wires
11) Disconnect the ON/OFF connector wires from the valve.
12) Disconnect the DC Sparker leads at the valve by removing 1 Phillips
screw.
DC Sparker Lead
14) Slighty lift out valve tray.
15) Disconnect the inlet gas line.
16) Replace valve and reverse steps.
MAINTENANCE
13) Remove the valve tray by undoing 12 screws.