Regency HZ54 Indoor Fireplace User Manual


 
HZ54 Regency Horizon
TM
Gas Fireplace
14
INSTALLATION
INSTALLATION
Vent restriction is required for certain venting installations, see the diagrams in the "Venting
Arrangements" section to determine if they are required for your installation.
The Vent Restrictor plate is located on the inside top of the rebox.
To set the vent restriction as indicated in the venting arrangements diagrams, refer to the following instructions;
1) Remove the glass door.
2) Remove the screws that hold the vent restrictor plate in place.
3) Adjust the vent restrictor plate to the required vent restrictor position as per the diagrams shown.
4) Once the vent restrictor plate is in the required position, secure with screws.
VENT RESTRICTOR POSITION
Vent Restrictor Settings for HZ54-NG
Vent Restrictor Settings for HZ54-LP
4.25”
3”
2”
Vent Restrictor Set 1
Factory Set Vent Restrictor
(No adjustment required)
Vent Restrictor Set 2
Vent Restrictor Set 3
4.25”
2”
1”
Vent Restrictor Set 1
Factory Set Vent Restrictor
(No adjustment required)
Vent Restrictor Set 3
Vent Restrictor Set 4