HZ54 Regency Horizon
TM
Gas Fireplace 33
INSTALLATION
INSTALLATION
OPTIONAL STAINLESS STEEL
REFLECTIVE PANEL INSTALLATION
1) Position the left side panel in place and fi t the bottom tab into the slot
at the bottom of the fi rebox as shown below. Repeat for right side
panel.
Fit side panel tab into slot
Left Side
Panel
Left side panel in position
2) Fit the back panel into position by clearing the pilot shield and fi t the
tabs on the bottom left and right side of the back panel into the slots
at the base of the fi rebox.
Secure the back panel in place by placing the brackets over the
screws on the top of the inside left and right side of the fi rebox and
tighten the screw to hold the bracket against the back panel.
Right side back panel tab fi tted into slot
Bracket shown in place on right side of the fi rebox
Back Panel
Right side panel in position
Before you start:
Stainless panels must be inspected for scratches and dimples prior to installation. All claims to be recorded at this time. Claims for
damage after installation will not receive consideration.
To protect the fi nish during installation and handling - cotton gloves MUST be worn at all times while handling the panels (even
when removing protective coating).
Stainless panels will discolor a little during normal operation. This is normal and should not be considered a defect.
All hand and fi nger marks MUST be cleaned off with a soft cloth and a stainless steel cleaner. Most stainless steel cleaners leave a
fi lm/residue on the surface of the panels. Use an ammonia based cleaner (ie. glass cleaner) to remove this fi lm before applying heat to
the unit. Failure to do this will result in burn stain on panels which you will be unable to remove. This is not a warranty item.