Quadra-Fire 5100I-GD-B Indoor Fireplace User Manual


 
5100-I ACT WOOD INSERT

April 21, 2010
R
438-0380E
E. Door Handle Assembly Replacement
1. Install washer on door handle shaft.
 
3. Install second washer(s) as shown.
 
 
over shaft
 
 
motion to desired location on handle.
CAUTION
 
Door handle needs to move smoothly.
Locknut
Door Cross
Section
Latch Cam
Spacing Washers
Square Key
Door Handle
Spring Handle
Frequency: As needed
By:
Task: 
Figure 34.1
 pages 21-22
for complete details.
2. Remove 2 screws on blower housing.
 
 
5. Remove 2 screws from blower and remove from
housing.
6. Attach new blower to housing.
7. Re-assemble in reverse order.
F. Blower Replacement
Frequency: As needed
By:
Task: 
Remove
2 Screws
Figure 34.2
Figure 34.3