INSTRUCTIONS PERTAINING TO THE INSTALLER 926.772.1 - GB/IE
The SIEMENS model QAC34 outdoor temperature sensor (optional extra) for weather compensation must be
connected to terminals 7-8 of terminal board M2 in gure 13.
The procedures for setting the gradient of the temperature curve “kt” vary depending on the accessories
connected to the boiler.
a) Without QAA73 room temperature regulator:
The temperature curve “kt” must be selected by setting parameter H532 as described in section 16 “setting
the boiler parameters”.
See graph 2 for selecting the curve referred to a room temperature of 20°C.
The chosen curve can be shifted by pressing the (2), button (2) on the boiler control panel, and modifying
the value displayed by pressing the and keys. See graph 3 for curve selection. (The example show
in graph 3 refers to the curve Kt=15).
Increase the value displayed if the room temperature required is not reached inside the premises for central
heating.
14.5 CONNECTING THE OUTDOOR TEMPERATURE SENSOR
Graph 2 Graph 3
TM = Flow temperature
Te = Composite outside temperature
Sth = Kt Curve