Pelco Not ICS110-CW Home Security System User Manual


 
10 C3406M-D (1/07)
6. Connect the power wires.
AC operation only:
If you are wiring more than one Camclosure integrated camera system to
the same transformer, connect one side of the transformer to the red wire on all units, and
connect the other side of the transformer to the black wire on all units. Failure to connect all of
the units the same way will cause the cameras to be out of phase with each other and may
produce a vertical roll when switching between cameras.
7. Reinstall the back box inside the cover. For vandal-resistant installations, rotate the back box
to position the conduit plug opposite the notch on the side of the cover. Use the two
8-32 x 0.375-inch Phillips pan head screws and washers (removed earlier) to secure the back
box to the cover.
Figure 3.
4S Electrical Box Installation
Voltage Red Wire Black Wire
12 VDC + Ground
24 VAC ~ ~
8-32 X 0.75-INCH
PHILLIPS FLAT
HEAD SCREWS
(SUPPLIED)
8-32 X 0.375-INCH
PHILLIPS PAN HEAD
SCREWS WITH WASHERS
(SUPPLIED)
COVER
BACK BOX
8-32 X 0.375-INCH
PHILLIPS PAN
HEAD SCREWS
(SUPPLIED WITH
ICS110-AP)
CEILING/
WALL
4S STANDARD
ELECTRICAL BOX
ADAPTER PLATE
(ICS110-AP)