30 C603M-A (11/07)
FRONT PANEL INDICATORS/FUNCTIONS
Network RJ-45, 10/100BASE-T
Power Blue
Status Green, amber, red
Network Link/Speed Amber, red
Network Activity Green
Video Green, red
POWER
Power Consumption 14.5 W, 50 BTU/H
Power Input 12 VDC ±10%
24 VAC ±10%
Power Connectors
4-Pin For RK5100PS-5U or NET5301PS
2-Pin For user-supplied power supply
ENVIRONMENTAL
Operating Temperature 41° to 95°F (5° to 35°C) at unit air intake
Storage Temperature -40° to 149°F (-40° to 65°C)
Operating Humidity 20% to 80%, noncondensing
Maximum Humidity Gradient 10% per hour
Operating Altitude -50 ft to 10,000 ft (-16 m to 3,048 m)
Operating Vibration 0.25 G at 3 Hz to 200 Hz at a sweep rate of 0.5 octave/minute
NOTE: The temperature at the unit air intake can be significantly higher than room temperature. Temperature is affected by rack configuration,
floor layout, air conditioning strategy, and other issues. To prevent performance failure and unit damage, make sure the temperature at the unit is
continuously within the operating temperature range.
PHYSICAL
Construction Sheet metal
Finish Gray metallic with black end caps, black matte finish
Dimension 8.75" D x 6.5" W x 1.2" H
(22.2 x 16.5 x 3.0 cm)
Mounting Desktop (feet), wall, or rack with options
Unit Weight 2.0 lb (0.9 kg)
STANDARDS/ORGANIZATIONS
• Pelco is a member of the MPEG-4 Industry Forum
• Pelco is a member of the Universal Plug and Play (UPnP) Forum
• Pelco is a member of the Universal Serial Bus (USB) Implementers Forum
• Pelco is a contributor to the International Standards for Organization/Electrotechnical Commission (ISO/IEC) Joint Technical Committee 1
(JTC1), “Information Technology,” Subcommittee 29, Working Group 11
• Compliance, ISO/IEC 14496 standard (also known as MPEG-4)
• Compliant with International Telecommunication Union (ITU) Recommendation G.711, “Pulse Code Modulations (PCM) of Voice Frequencies”